published 2013-03-21CVE-2013-0679: Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote…
PriorityP423medium4CVSS 2.0
AVNACLAuSCPINAN
EPSS
2.33%
81.5th percentile
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Affected
6 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | simatic_pcs7 | <= 8.0 | — |
| siemens | simatic_pcs7 | — | — |
| siemens | wincc | <= 7.1 | — |
| siemens | wincc | — | — |
| siemens | wincc | — | — |
| siemens | wincc | — | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-rg3v-p933-jrxw: Directory traversal vulnerability in the web server in Siemens WinCC before 7
ghsa_unreviewed·2022-05-17
CVE-2013-0679 [MEDIUM] CWE-22 GHSA-rg3v-p933-jrxw: Directory traversal vulnerability in the web server in Siemens WinCC before 7
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
CISA ICS
Siemens WinCC 7.0 SP3 Multiple Vulnerabilities
cisa_ics·2013-05-08
Siemens WinCC 7.0 SP3 Multiple Vulnerabilities
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens WinCC 7.0 SP3 Multiple Vulnerabilities
Last RevisedMay 08, 2013
Alert CodeICSA-13-079-02
## Overview
This advisory provides mitigation details for vulnerabilities that impact the Siemens SIMATIC WinCC.
Positive Technologies and Siemens ProductCERT have identified multiple vulnerabilities in the Siemens SIMATIC WinCC, which is used to configure SIMATIC operator devices. Siemens has produced a software update that fully resolves these vulnerabilities. Exploitation of these vulnerabilities could allow a denial-of-service (DoS) condition, unauthorized read access to files,
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdfhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdfhttp://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdfhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf