CVE-2018-11421
published 2019-07-03CVE-2018-11421: Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and…
PriorityP352critical9.8CVSS 3.0
AVNACLPRNUINSUCHIHAH
EPSS
0.91%
55.7th percentile
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| moxa | oncell_g3150-hspa-t_firmware | <= 1.6 | — |
| moxa | oncell_g3150-hspa_firmware | <= 1.6 | — |
CVSS provenance
nvdv3.09.8CRITICALCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv2.05.0MEDIUMAV:N/AC:L/Au:N/C:P/I:N/A:N
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2019-07-03
Published