CVE-2018-11463
published 2018-12-12CVE-2018-11463: A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6…
PriorityP340high7.8CVSS 3.0
AVLACLPRLUINSUCHIHAH
EPSS
0.46%
36.5th percentile
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Affected
3 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | sinumerik_828d_v4.7_firmware | <= 4.7 | — |
| siemens | sinumerik_840d_sl_v4.7_firmware | <= 4.7 | — |
| siemens | sinumerik_840d_sl_v4.8_firmware | <= 4.8 | — |
CVSS provenance
nvdv3.07.8HIGHCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
nvdv2.04.6MEDIUMAV:L/AC:L/Au:N/C:P/I:P/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-82xh-8r83-mpfq: A vulnerability has been identified in SINUMERIK 808D V4
ghsa_unreviewed·2022-05-13
CVE-2018-11463 [HIGH] CWE-119 GHSA-82xh-8r83-mpfq: A vulnerability has been identified in SINUMERIK 808D V4
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CISA ICS
Siemens SINUMERIK Controllers (Update A)
cisa_ics·2018-12-11
Siemens SINUMERIK Controllers (Update A)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SINUMERIK Controllers (Update A)
Last RevisedMarch 12, 2019
Alert CodeICSA-18-345-02
## 1. EXECUTIVE SUMMARY
-
CVSS v3 10.0
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Siemens
- Equipment: SINUMERIK Controllers
- Vulnerabilities: Heap-based Buffer Overflow, Integer Overflow or Wraparound, Protection Mechanism Failure, Permissions, Privileges, and Access Controls, Stack-based Buffer Overflow, Uncaught Exception
## 2. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled ICSA-18-345-02 Siemens SINUMERIK Con
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2018-12-12
Published