CVE-2018-17901
published 2018-10-17CVE-2018-17901: LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on…
PriorityP338high7.8CVSS 3.0
AVLACLPRNUIRSUCHIHAH
EPSS
1.57%
72.2th percentile
LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| lcds | laquis_scada | <= 4.1.0.3870 | — |
| lcds_le_o_consultoria_e_desenvolvimento_de_sistemas_ltda_me | laquis_scada | — | — |
CVSS provenance
nvdv3.07.8HIGHCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
nvdv2.06.8MEDIUMAV:N/AC:M/Au:N/C:P/I:P/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-rjwr-3c6v-3hrm: LAquis SCADA Versions 4
ghsa_unreviewed·2022-05-13
CVE-2018-17901 [HIGH] CWE-787 GHSA-rjwr-3c6v-3hrm: LAquis SCADA Versions 4
LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.
CISA ICS
LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA
cisa_ics·2019-01-15·CVSS 9.8
[CRITICAL] LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA
Last RevisedJanuary 15, 2019
Alert CodeICSA-18-289-01
## 1. EXECUTIVE SUMMARY
-
CVSS v3 7.8
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: LCDS – Leão Consultoria e Desenvolvimento de Sistemas LTDA ME
- Equipment: LAquis SCADA
- Vulnerabilities: Untrusted Pointer Dereference, Out-of-Bounds Read, Integer Overflow to Buffer Overflow, Path Traversal, Out-of-bounds Write, and Stack-based Buffer Overflow
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could