CVE-2019-10929
published 2019-08-13CVE-2019-10929: A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions)…
PriorityP431medium5.9CVSS 3.1
AVNACHPRNUINSUCNIHAN
EPSS
0.98%
58.2th percentile
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Affected
27 ranges· showing 25
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | simatic_cp_1626 | — | — |
| siemens | simatic_et_200sp_open_controller_cpu_1515sp_pc | — | — |
| siemens | simatic_et_200sp_open_controller_cpu_1515sp_pc2 | — | — |
| siemens | simatic_hmi_panel | — | — |
| siemens | simatic_net_pc | < 16 | 16 |
| siemens | simatic_net_pc_software_v14 | — | — |
| siemens | simatic_net_pc_software_v15 | — | — |
| siemens | simatic_s7-1200_cpu_1211c_firmware | <= 4.0 | — |
| siemens | simatic_s7-1200_cpu_1212c_firmware | <= 4.0 | — |
| siemens | simatic_s7-1200_cpu_1214c_firmware | <= 4.0 | — |
| siemens | simatic_s7-1200_cpu_1215c_firmware | <= 4.0 | — |
| siemens | simatic_s7-1200_cpu_1217c_firmware | <= 4.0 | — |
| siemens | simatic_s7-1200_cpu_family | — | — |
| siemens | simatic_s7-1500_cpu_family | — | — |
| siemens | simatic_s7-1500_software_controller | — | — |
| siemens | simatic_s7-plcsim_advanced | — | — |
| siemens | simatic_step_7 | < 16 | 16 |
| siemens | simatic_step_7 | — | — |
| siemens | simatic_tim_1531_irc_firmware | < 2.1 | 2.1 |
| siemens | simatic_wincc | < 16 | 16 |
| siemens | simatic_wincc | — | — |
| siemens | simatic_wincc_oa | — | — |
| siemens | simatic_wincc_open_architecture | <= 3.15 | — |
| siemens | simatic_wincc_open_architecture | — | — |
| siemens | simatic_wincc_runtime_advanced | — | — |
CVSS provenance
nvdv3.15.9MEDIUMCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
nvdv2.04.3MEDIUMAV:N/AC:M/Au:N/C:N/I:P/A:N
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-77j2-3682-mqmj: A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2
ghsa_unreviewed·2022-05-24
CVE-2019-10929 [MEDIUM] CWE-327 GHSA-77j2-3682-mqmj: A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7-1200 CPU family (All versions >= V4.0), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-PLCSIM Advanced (All versions). An attacker in a Man-in-the-Middle position could potentially modify network traffic exchanged on port 102/tcp, due to certain properties in the calculation used for integrity protection. In order to exploit the vulnerability, an attacker must be able to perform a Man-in-the-Middle attack. The vulnerability could impact the integrity of the communication. No public exploitation of the vulnerability was known at the time of advisory publicati
CISA ICS
Siemens SIMATIC Products (Update C)
cisa_ics·2022-04-14
Siemens SIMATIC Products (Update C)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SIMATIC Products (Update C)
Last RevisedApril 14, 2022
Alert CodeICSA-19-344-04
## 1. EXECUTIVE SUMMARY
- CVSS v3 3.7
- ATTENTION: Exploitable remotely
- Vendor: Siemens
- Equipment: SIMATIC CP 1626; HMI Panel (incl. SIPLUS variants); NET PC software; STEP 7 (TIA Portal); WinCC (TIA Portal); WinCC OA; WinCC Runtime (Pro and Advanced); TIM 1531 IRC (incl. SIPLUS variant)
- Vulnerability: Exposed Dangerous Method or Function
## 2. UPDATE INFORMATION
This updated advisory is a follow-up to the advisory update titled ICSA-19-344-04 Siemens SIMATIC Products (Update B) t
CISA ICS
Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)
cisa_ics·2020-03-10·CVSS 7.5
[HIGH] Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)
Last RevisedAugust 11, 2022
Alert CodeICSA-19-344-06
## 1. EXECUTIVE SUMMARY
- CVSS v3 5.3
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Siemens
- Equipment: SIMATIC S7-1200 and S7-1500 CPU families
- Vulnerabilities: Use of a Broken or Risky Cryptographic Algorithm, Missing Support for Integrity Check
## 2. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled ICSA-19-344-06 Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update A) that was published Ma
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdfhttps://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdfhttps://www.us-cert.gov/ics/advisories/icsa-19-344-04https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdfhttps://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdfhttps://www.us-cert.gov/ics/advisories/icsa-19-344-04
2019-08-13
Published