CVE-2019-18319
published 2019-12-12CVE-2019-18319: A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application…
PriorityP337high7.5CVSS 3.1
AVNACLPRNUINSUCNINAH
EPSS
1.05%
60.3th percentile
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18318. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Affected
3 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | sppa-t3000_application_server | < r8.2 | r8.2 |
| siemens | sppa-t3000_application_server | — | — |
| siemens | sppa-t3000_application_server | — | — |
CVSS provenance
nvdv3.17.5HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
nvdv2.05.0MEDIUMAV:N/AC:L/Au:N/C:N/I:N/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-6chg-8whj-347g: A vulnerability has been identified in SPPA-T3000 Application Server (All versions)
ghsa_unreviewed·2022-05-24·CVSS 7.5
CVE-2019-18319 [HIGH] CWE-287 GHSA-6chg-8whj-347g: A vulnerability has been identified in SPPA-T3000 Application Server (All versions)
A vulnerability has been identified in SPPA-T3000 Application Server (All versions). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18318. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
GHSA
GHSA-8hq9-6jgm-qf6f: A vulnerability has been identified in SPPA-T3000 Application Server (All versions)
ghsa_unreviewed·2022-05-24·CVSS 7.5
CVE-2019-18318 [HIGH] CWE-287 GHSA-8hq9-6jgm-qf6f: A vulnerability has been identified in SPPA-T3000 Application Server (All versions)
A vulnerability has been identified in SPPA-T3000 Application Server (All versions). An attacker with network access to the Application Server can cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
GHSA
GHSA-8c6q-359m-h9qj: A vulnerability has been identified in SPPA-T3000 Application Server (All versions)
ghsa_unreviewed·2022-05-24·CVSS 7.5
CVE-2019-18317 [HIGH] CWE-287 GHSA-8c6q-359m-h9qj: A vulnerability has been identified in SPPA-T3000 Application Server (All versions)
A vulnerability has been identified in SPPA-T3000 Application Server (All versions). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18318 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CISA ICS
Siemens SPPA-T3000 (Update A)
cisa_ics·2019-12-17
Siemens SPPA-T3000 (Update A)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SPPA-T3000 (Update A)
Last RevisedMarch 10, 2020
Alert CodeICSA-19-351-02
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Siemens
- Equipment: SPPA-T3000
- Vulnerabilities: Improper Input Validation, Deserialization of Untrusted Data, Improper Authentication, Cleartext Transmission of Sensitive Information, Unrestricted Upload of File with Dangerous Type, Heap-based Buffer Overflow, Integer Overflow or Wraparound, Out-of-bounds Read, Improper Access Control, Stack-based Buffer Overflow, SFP Secondary Cluste
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2019-12-12
Published