CVE-2019-19293
published 2020-03-10CVE-2019-19293: A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains a…
PriorityP426medium6.1CVSS 3.1
AVNACLPRNUIRSCCLILAN
EPSS
1.25%
65.7th percentile
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains a
reflected Cross-site Scripting (XSS) vulnerability
that could allow an unauthenticated remote attacker to steal sensitive data
or execute administrative actions on behalf of a legitimate administrator
of the CCS web interface.
Affected
1 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | control_center_server | — | — |
CVSS provenance
nvdv3.16.1MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
nvdv2.04.3MEDIUMAV:N/AC:M/Au:N/C:N/I:P/A:N
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens and PKE SiNVR/SiVMS Video Server (Update B)
cisa_ics·2021-04-20·CVSS 6.5
[MEDIUM] Siemens and PKE SiNVR/SiVMS Video Server (Update B)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens and PKE SiNVR/SiVMS Video Server (Update B)
Last RevisedAugust 10, 2021
Alert CodeICSA-20-070-01
## 1. EXECUTIVE SUMMARY
- CVSS v3 7.5
- ATTENTION: Exploitable remotely/low attack complexity
- Vendors: Siemens and PKE
- Equipment: SiNVR/SiVMS Video Server
- Vulnerabilities: Cleartext Storage in a File or on Disk, Path Traversal, Improper Input Validation, Weak Cryptography for Passwords
## 2. UPDATE INFORMATION
This updated advisory is a follow-up to the advisory update titled ICSA-20-070-01 Siemens SiNVR 3 (Update A) that was published April 20, 2021, to the ICS w
CISA ICS
Siemens and PKE Control Center Server
cisa_ics·2021-04-13·CVSS 4.9
[MEDIUM] Siemens and PKE Control Center Server
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens and PKE Control Center Server
Last RevisedApril 13, 2021
Alert CodeICSA-21-103-10
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.9
- ATTENTION: Exploitable remotely/low attack complexity
- Vendors: Siemens/PKE
- Equipment: Control Center Server (CCS)
- Vulnerabilities: Cleartext Storage of Sensitive Information in GUI, Improper Authentication, Relative Path Traversal, Use of a Broken or Risky Cryptographic Algorithm, Exposed Dangerous Method or Function, Path Traversal, Cleartext Storage in a File or on Disk, SQL Injection, Cross-site Scripting, Insufficient Logging
## 2. RISK
GHSA
GHSA-2wg4-jvq7-qmph: A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions)
ghsa_unreviewed·2022-05-24
CVE-2019-19293 [MEDIUM] CWE-79 GHSA-2wg4-jvq7-qmph: A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions)
A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The web interface of the SiNVR 3 Central Control Server (CCS) contains a reflected Cross-site Scripting (XSS) vulnerability that could allow an unauthenticated remote attacker to steal sensitive data or execute administrative actions on behalf of a legitimate administrator of the CCS web interface.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2020-03-10
Published