CVE-2019-5319
published 2021-03-30CVE-2019-5319: A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17…
PriorityP355critical9.8CVSS 3.1
AVNACLPRNUINSUCHIHAH
EPSS
2.41%
82.2th percentile
A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
Affected
6 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| arubanetworks | instant | 6.4.0.0 – 6.4.4.8-4.2.4.17 | — |
| arubanetworks | instant | >= 6.5.0.0 < 6.5.4.17 | 6.5.4.17 |
| arubanetworks | instant | >= 8.3.0.0 < 8.3.0.13 | 8.3.0.13 |
| arubanetworks | instant | >= 8.5.0.0 < 8.5.0.7 | 8.5.0.7 |
| arubanetworks | instant | >= 8.6.0.0 < 8.6.0.3 | 8.6.0.3 |
| siemens | scalance_w1750d_firmware | < 8.7.0 | 8.7.0 |
CVSS provenance
nvdv3.19.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv2.010.0CRITICALAV:N/AC:L/Au:N/C:C/I:C/A:C
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens SCALANCE W1750D (Update B)
cisa_ics·2021-08-10·CVSS 7.2
[HIGH] Siemens SCALANCE W1750D (Update B)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SCALANCE W1750D (Update B)
Last RevisedOctober 14, 2021
Alert CodeICSA-21-131-14
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SCALANCE W1750D
- Vulnerabilities: Improper Authentication, Classic Buffer Overflow, Command Injection, Improper Input Validation, Race Condition, Cross-site Scripting, Basic XSS, Uncontrolled Resource Consumption
## 2. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled ICSA-21-131-14 Siemens SCALANCE W1750D (Update A) that wa
GHSA
GHSA-5r54-pmvg-4gqx: A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6
ghsa_unreviewed·2022-05-24
CVE-2019-5319 [CRITICAL] CWE-120 GHSA-5r54-pmvg-4gqx: A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6
A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2021-03-30
Published