CVE-2019-7280
published 2019-07-01CVE-2019-7280: Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote…
PriorityP350high8.8CVSS 3.1
AVNACLPRLUINSUCHIHAH
EPSS
2.35%
81.6th percentile
Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication.
Affected
1 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| primasystems | flexair | <= 2.3.38 | — |
CVSS provenance
nvdv3.18.8HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
nvdv2.04.0MEDIUMAV:N/AC:L/Au:S/C:P/I:N/A:N
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Prima Systems FlexAir
cisa_ics·2019-07-30·CVSS 7.2
[HIGH] Prima Systems FlexAir
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Prima Systems FlexAir
Last RevisedJuly 30, 2019
Alert CodeICSA-19-211-02
## 1. EXECUTIVE SUMMARY
- CVSS v3 10.0
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Prima Systems
- Equipment: FlexAir
- Vulnerabilities: OS Command Injection, Unrestricted Upload of File with Dangerous Type, Cross-site Request Forgery, Small Space of Random Values, Cross-site Scripting, Exposure of Backup file to Unauthorized Control Sphere, Improper Authentication, Use of Hard-coded Credentials
## 2. RISK EVALUATION
Exploitation of these vulnerabilities may allow an attacke
GHSA
GHSA-65c7-88xp-pcv7: Prima Systems FlexAir devices have an Insufficient Session-ID Length
ghsa_unreviewed·2022-05-24
CVE-2019-7280 [HIGH] CWE-613 GHSA-65c7-88xp-pcv7: Prima Systems FlexAir devices have an Insufficient Session-ID Length
Prima Systems FlexAir devices have an Insufficient Session-ID Length.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2019-07-01
Published