CVE-2019-8275
published 2019-03-08CVE-2019-8275: UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote…
PriorityP359critical9.8CVSS 3.1
AVNACLPRNUINSUCHIHAH
EPSS
3.97%
89.2th percentile
UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Affected
5 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| kaspersky_lab | ultravnc | — | — |
| siemens | sinumerik_access_mymachine_p2p | < 4.8 | 4.8 |
| siemens | sinumerik_pcu_base_win10_software_ipc | < 14.00 | 14.00 |
| siemens | sinumerik_pcu_base_win7_software_ipc | <= 12.01 | — |
| uvnc | ultravnc | < 1.2.2.3 | 1.2.2.3 |
CVSS provenance
nvdv3.19.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv2.07.5HIGHAV:N/AC:L/Au:N/C:P/I:P/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens SIMATIC UltraVNC HMI WinCC Products
cisa_ics·2021-05-11·CVSS 7.5
[HIGH] Siemens SIMATIC UltraVNC HMI WinCC Products
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SIMATIC UltraVNC HMI WinCC Products
Last RevisedMay 11, 2021
Alert CodeICSA-21-131-11
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SIMATIC HMIs/WinCC Products
- Vulnerabilities: Improper Initialization, Out-of-bounds Read, Heap-based Buffer Overflow, Stack-based Buffer Overflow, Access of Memory Location After End of Buffer, Improper Null Termination
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow remote code execution, information disclosure, and deni
CISA ICS
Siemens SINAMICS Medium Voltage Products Remote Access (Update B)
cisa_ics·2021-05-11·CVSS 7.5
[HIGH] Siemens SINAMICS Medium Voltage Products Remote Access (Update B)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SINAMICS Medium Voltage Products Remote Access (Update B)
Last RevisedAugust 10, 2021
Alert CodeICSA-21-131-04
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely
- Vendor: Siemens
- Equipment: SINAMICS Medium Voltage Products, Remote Access
- Vulnerabilities: Improper Restriction of Operations Within the Bounds of a Memory Buffer, Access of Memory Location After End of Buffer, Uncontrolled Resource Consumption, Improper Initialization, Out-of-Bound Read, Heap-based Buffer Overflow, Stack-based Buffer Overflow, Improper Null Termination
## 2. UPD
CISA ICS
Siemens SINUMERIK
cisa_ics·2020-06-12·CVSS 9.8
[CRITICAL] Siemens SINUMERIK
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SINUMERIK
Last RevisedJune 12, 2020
Alert CodeICSA-20-161-06
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Siemens
- Equipment: SINUMERIK
- Vulnerabilities: Buffer Underflow, Heap-based Buffer Overflow, Improper Initialization, Out-of-bounds Read, Stack-based Buffer Overflow, Access of Memory Location After End of Buffer, Off-by-one Error, Improper Null Termination, Improper Initialization
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow remote code execution, informati
GHSA
GHSA-hhw7-p92g-vp7v: UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by
ghsa_unreviewed·2022-05-13
CVE-2019-8275 [CRITICAL] GHSA-hhw7-p92g-vp7v: UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by
UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfhttps://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdfhttps://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdfhttps://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11https://www.us-cert.gov/ics/advisories/icsa-20-161-06https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfhttps://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdfhttps://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdfhttps://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11https://www.us-cert.gov/ics/advisories/icsa-20-161-06
2019-03-08
Published