CVE-2021-0507
published 2021-06-21CVE-2021-0507: In handle_rc_metamsg_cmd of btif_rc.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution over…
PriorityP349high8.8CVSS 3.1
AVAACLPRNUINSUCHIHAH
EPSS
1.01%
59.5th percentile
In handle_rc_metamsg_cmd of btif_rc.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution over Bluetooth with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-8.1 Android-9 Android-10Android ID: A-181860042
Affected
10 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| android | — | — | |
| android | — | — | |
| android | — | — | |
| android | — | — | |
| android | — | — | |
| android | — | — | |
| platform | system_bt | >= 10:0 < 10:2021-06-01 | 10:2021-06-01 |
| platform | system_bt | >= 11:0 < 11:2021-06-01 | 11:2021-06-01 |
| platform | system_bt | >= 8.1:0 < 8.1:2021-06-01 | 8.1:2021-06-01 |
| platform | system_bt | >= 9:0 < 9:2021-06-01 | 9:2021-06-01 |
CVSS provenance
nvdv3.18.8HIGHCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv2.08.3HIGHAV:A/AC:L/Au:N/C:C/I:C/A:C
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens SIMATIC
cisa_ics·2024-03-14
Siemens SIMATIC
ICS Advisory
##
Siemens SIMATIC
Release DateMarch 14, 2024
Alert CodeICSA-24-074-07
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SIMATIC
- Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Input Validation, Missing Encryption of Sensitive Data, Incorrect Permission Assignment for Critical Resource, Expected Beha
Android
CVE-2021-0507: Android Security Bulletin 2021-06-01
CVE: CVE-2021-0507
Severity: CRITICAL
Type: RCE
Affected AOSP versions: 8
vendor_android·2021-06-01·CVSS 8.8
CVE-2021-0507 [HIGH] CVE-2021-0507: Android Security Bulletin 2021-06-01
CVE: CVE-2021-0507
Severity: CRITICAL
Type: RCE
Affected AOSP versions: 8
Android Security Bulletin 2021-06-01
CVE: CVE-2021-0507
Severity: CRITICAL
Type: RCE
Affected AOSP versions: 8.1, 9, 10, 11
References: A-181860042
GHSA
GHSA-g327-hh94-x2r8: In handle_rc_metamsg_cmd of btif_rc
ghsa_unreviewed·2022-05-24
CVE-2021-0507 [HIGH] CWE-787 GHSA-g327-hh94-x2r8: In handle_rc_metamsg_cmd of btif_rc
In handle_rc_metamsg_cmd of btif_rc.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution over Bluetooth with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-8.1 Android-9 Android-10Android ID: A-181860042
OSV
CVE-2021-0507: In handle_rc_metamsg_cmd of btif_rc
osv·2021-06-01
CVE-2021-0507 CVE-2021-0507: In handle_rc_metamsg_cmd of btif_rc
In handle_rc_metamsg_cmd of btif_rc.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution over Bluetooth with no additional execution privileges needed. User interaction is not needed for exploitation.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2021-06-21
Published