CVE-2021-22996
published 2021-03-31CVE-2021-22996: On all 7.x versions (fixed in 8.0.0), when set up for auto failover, a BIG-IQ Data Collection Device (DCD) cluster member that receives an undisclosed message…
PriorityP338high7.5CVSS 3.1
AVNACLPRNUINSUCNINAH
EPSS
0.97%
57.9th percentile
On all 7.x versions (fixed in 8.0.0), when set up for auto failover, a BIG-IQ Data Collection Device (DCD) cluster member that receives an undisclosed message may cause the corosync process to abort. This behavior may lead to a denial-of-service (DoS) and impact the stability of a BIG-IQ high availability (HA) cluster. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Affected
3 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| f5 | big-iq | — | — |
| f5 | big-iq_centralized_management | — | — |
| f5 | big-iq_centralized_management | >= 7.0.0 < 8.0.0 | 8.0.0 |
CVSS provenance
nvdv3.17.5HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
nvdv2.05.0MEDIUMAV:N/AC:L/Au:N/C:N/I:N/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-65mv-m6g8-v775: On all 7
ghsa_unreviewed·2022-05-24
CVE-2021-22996 [HIGH] GHSA-65mv-m6g8-v775: On all 7
On all 7.x versions (fixed in 8.0.0), when set up for auto failover, a BIG-IQ Data Collection Device (DCD) cluster member that receives an undisclosed message may cause the corosync process to abort. This behavior may lead to a denial-of-service (DoS) and impact the stability of a BIG-IQ high availability (HA) cluster. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
F5
CVE-2021-22996: On all 7
vendor_f5·2021-03-31·CVSS 7.5
CVE-2021-22996 [HIGH] CVE-2021-22996: On all 7
CVE-2021-22996: On all 7
On all 7.x versions (fixed in 8.0.0), when set up for auto failover, a BIG-IQ Data Collection Device (DCD) cluster member that receives an undisclosed message may cause the corosync process to abort. This behavior may lead to a denial-of-service (DoS) and impact the stability of a BIG-IQ high availability (HA) cluster. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Affected Products: BIG-IQ
Affected Versions: 7.0.0 - 8.0.0
F5 Advisory Articles: K16352404
F5 References: https://support.f5.com/csp/article/K16352404
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2021-03-31
Published