CVE-2021-29847
published 2021-12-15CVE-2021-29847: BMC firmware (IBM Power System S821LC Server (8001-12C) OP825.50) configuration changed to allow an authenticated user to open an insecure communication…
PriorityP429medium5.9CVSS 3.1
AVNACHPRNUINSUCHINAN
EPSS
1.02%
63.3th percentile
BMC firmware (IBM Power System S821LC Server (8001-12C) OP825.50) configuration changed to allow an authenticated user to open an insecure communication channel which could allow an attacker to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 205267.
Affected
6 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| ibm | power_hardware_management_console_firmware | < op825.51 | op825.51 |
| ibm | power_system_cs821lc_firmware | < op825.51 | op825.51 |
| ibm | power_system_cs822lc_firmware | < op825.51 | op825.51 |
| ibm | power_system_s821lc_firmware | < op825.51 | op825.51 |
| ibm | power_system_s821lc_server | — | — |
| ibm | power_system_s822lc_firmware | < op825.51 | op825.51 |
CVSS provenance
nvdv3.15.9MEDIUMCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
nvdv3.05.3MEDIUMCVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N
nvdv2.04.3MEDIUMAV:N/AC:M/Au:N/C:P/I:N/A:N