cbcvebase.
CVE-2021-31342
published 2021-06-08

CVE-2021-31342: The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of…

PriorityP348high8.8CVSS 3.1
AVNACLPRNUIRSUCHIHAH
EPSS
2.50%
82.9th percentile
The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Affected

2 ranges
VendorProductVersion rangeFixed in
siemenssolid_edge_se2020_firmware< 2020mp142020mp14
siemenssolid_edge_se2021_firmware< se2021mp5se2021mp5

CVSS provenance

nvdv3.18.8HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H