CVE-2021-37734
published 2021-10-12CVE-2021-37734: A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant…
PriorityP336medium6.5CVSS 3.1
AVNACLPRLUINSUCHINAN
EPSS
0.95%
57.1th percentile
A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.19 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 and below; Aruba Instant 8.8.x.x: 8.8.0.0 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.
Affected
6 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| arubanetworks | aruba_instant | >= 6.4.0.2-4.1.0.0 < 6.4.4.8-4.2.4.19 | 6.4.4.8-4.2.4.19 |
| arubanetworks | aruba_instant | >= 6.5.4.0 < 6.5.4.20 | 6.5.4.20 |
| arubanetworks | aruba_instant | >= 8.5.0.0 < 8.5.0.13 | 8.5.0.13 |
| arubanetworks | aruba_instant | >= 8.6.0.0 < 8.6.0.12 | 8.6.0.12 |
| arubanetworks | aruba_instant | >= 8.7.0.0 < 8.7.1.4 | 8.7.1.4 |
| siemens | scalance_w1750d_firmware | >= 8.7.1.3 | — |
CVSS provenance
nvdv3.16.5MEDIUMCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
nvdv2.04.0MEDIUMAV:N/AC:L/Au:S/C:P/I:N/A:N
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens SCALANCE W1750D (Update A)
cisa_ics·2022-11-11·CVSS 9.8
[CRITICAL] Siemens SCALANCE W1750D (Update A)
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SCALANCE W1750D (Update A)
Last RevisedOctober 13, 2022
Alert CodeICSA-21-315-06
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SCALANCE W1750D
- Vulnerabilities: Improper Restriction of Operations Within the Bounds of a Memory Buffer, Command Injection, Path Traversal
## 2. UPDATE INFORMATION
This updated advisory is a follow-up to the advisory update titled ICSA-21-315-06 Siemens SCALANCE W1750D that was published November 11, 2022, to the ICS webpage on www.cisa.gov/uscert.
## 3. RISK
GHSA
GHSA-3q59-83xj-cggf: A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6
ghsa_unreviewed·2022-05-24
CVE-2021-37734 [MEDIUM] CWE-668 GHSA-3q59-83xj-cggf: A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6
A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.19 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 and below; Aruba Instant 8.8.x.x: 8.8.0.0 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2021-10-12
Published