CVE-2021-38424
published 2021-11-03CVE-2021-38424: The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may…
PriorityP335high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
EPSS
0.48%
37.8th percentile
The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| delta_electronics | dialink | All – 1.2.4.0 | — |
| deltaww | dialink | <= 1.2.4.0 | — |
CVSS provenance
nvdv3.17.8HIGHCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
nvdv2.06.8MEDIUMAV:N/AC:M/Au:N/C:P/I:P/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Delta Electronics DIALink
cisa_ics·2021-10-21·CVSS 8.8
[HIGH] Delta Electronics DIALink
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Delta Electronics DIALink
Last RevisedOctober 21, 2021
Alert CodeICSA-21-294-02
## 1. EXECUTIVE SUMMARY
- CVSS v3 8.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Delta Electronics
- Equipment: DIALink
- Vulnerabilities: Cleartext Transmission of Sensitive Information, Cross-site Scripting, Improper Neutralization of Formula Elements in a CSV File, Cleartext Storage of Sensitive Information, Uncontrolled Search Path Element, Incorrect Default Permissions
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to a
GHSA
GHSA-39mq-9cjh-6382: The tag interface of Delta Electronics DIALink versions 1
ghsa_unreviewed·2022-05-24
CVE-2021-38424 [HIGH] CWE-1236 GHSA-39mq-9cjh-6382: The tag interface of Delta Electronics DIALink versions 1
The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2021-11-03