CVE-2022-1522
published 2022-09-06CVE-2022-1522: The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which…
PriorityP426medium5.3CVSS 3.1
AVNACLPRNUINSUCNILAN
EPSS
0.46%
36.6th percentile
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| cognex | 3d-a1000_dimensioning_system | all – 1.0.3 (3354) | — |
| cognex | 3d-a1000_dimensioning_system_firmware | <= 1.0.3\(3354\) | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Cognex 3D-A1000 Dimensioning System
cisa_ics·2022-09-06·CVSS 9.8
[CRITICAL] Cognex 3D-A1000 Dimensioning System
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Cognex 3D-A1000 Dimensioning System
Last RevisedSeptember 06, 2022
Alert CodeICSA-22-249-03
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely, low attack complexity
- Vendor: Cognex
- Equipment: 3D-A1000 Dimensioning System
- Vulnerabilities: Missing Authentication for Critical Function, Improper Output Neutralization for Logs, Client-side Enforcement of Server-side Security
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could result in unauthorized password changes, escalation of privileges, falsifying of password logs, and by
GHSA
GHSA-j3gr-58v5-64m3: The Cognex 3D-A1000 Dimensioning System in firmware version 1
ghsa_unreviewed·2022-09-07
CVE-2022-1522 [MEDIUM] CWE-117 GHSA-j3gr-58v5-64m3: The Cognex 3D-A1000 Dimensioning System in firmware version 1
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2022-09-06
Published