CVE-2022-24315
published 2022-02-09CVE-2022-24315: A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected…
PriorityP347high7.5CVSS 3.1
AVNACLPRNUINSUCNINAH
EPSS
19.25%
97.0th percentile
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Affected
1 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| schneider-electric | interactive_graphical_scada_system_data_server | <= 15.0.0.22020 | — |
CVSS provenance
nvdv3.17.5HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
nvdv2.05.0MEDIUMAV:N/AC:L/Au:N/C:N/I:N/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Schneider Electric IGSS
cisa_ics·2022-02-15·CVSS 9.8
[CRITICAL] Schneider Electric IGSS
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Schneider Electric IGSS
Last RevisedFebruary 15, 2022
Alert CodeICSA-22-046-01
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Schneider Electric
- Equipment: IGSS (Interactive Graphical SCADA System)
- Vulnerabilities: Integer Overflow or Wraparound, Path Traversal, Classic Buffer Overflow, Out-of-bounds Read, Improper Initialization, Missing Authorization
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could result in a variety of issues, including disclosure of data and loss of control of the
GHSA
GHSA-wrrm-pwrp-4mqm: A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message