CVE-2022-32262
published 2022-06-14CVE-2022-32262: A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is…
PriorityP262critical9.8CVSS 3.1
AVNACLPRNUINSUCHIHAH
EPSS
2.42%
82.3th percentile
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | sinema_remote_connect_server | < V3.1 | V3.1 |
| siemens | sinema_remote_connect_server | < 3.1 | 3.1 |
CVSS provenance
nvdv3.19.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv2.07.5HIGHAV:N/AC:L/Au:N/C:P/I:P/A:P
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-pxh7-rqm4-2h48: A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3
ghsa_unreviewed·2022-06-15
CVE-2022-32262 [CRITICAL] CWE-77 GHSA-pxh7-rqm4-2h48: A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.
CISA ICS
Siemens SINEMA Remote Connect Server
cisa_ics·2022-06-16·CVSS 3.7
[LOW] Siemens SINEMA Remote Connect Server
## Archived Content In an effort to keep CISA.gov current, the archive contains outdated information that may not reflect current policy or programs.
ICS Advisory
##
Siemens SINEMA Remote Connect Server
Last RevisedJune 16, 2022
Alert CodeICSA-22-167-17
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SINEMA Remote Connect Server
- Vulnerabilities: Multiple
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges, disclose information, or allow code execution.
## 3. TECHNICAL DETAILS
## 3.1 AFFECTED PRODUCTS
The following Siemens products are affected:
- Siemens SINEMA Remote Connect Server: All v
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2022-06-14