CVE-2022-39152
published 2022-09-13CVE-2022-39152: A vulnerability has been identified in Parasolid V33.1 (All versions = V33.1.262 = V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3)…
high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
A vulnerability has been identified in Parasolid V33.1 (All versions = V33.1.262 = V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)
Affected
14 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | parasolid | >= 33.1 < 33.1.263 | 33.1.263 |
| siemens | parasolid | >= 34.0 < 34.0.252 | 34.0.252 |
| siemens | parasolid | >= 34.1 < 34.1.242 | 34.1.242 |
| siemens | parasolid | >= 35.0 < 35.0.164 | 35.0.164 |
| siemens | parasolid_v33.1 | — | — |
| siemens | parasolid_v33.1 | — | — |
| siemens | parasolid_v34.0 | — | — |
| siemens | parasolid_v34.1 | — | — |
| siemens | parasolid_v35.0 | — | — |
| siemens | parasolid_v35.0 | — | — |
| siemens | simcenter_femap | >= 2022.1 < 2022.1.3 | 2022.1.3 |
| siemens | simcenter_femap | >= 2022.2 < 2022.2.2 | 2022.2.2 |
| siemens | simcenter_femap_v2022.1 | — | — |
| siemens | simcenter_femap_v2022.2 | — | — |