CVE-2023-1138
published 2023-03-27CVE-2023-1138: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve…
PriorityP346high7.5CVSS 3.1
AVNACLPRNUINSUCHINAN
EPSS
0.57%
42.9th percentile
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| delta_electronics | infrasuite_device_master | < 1.0.5 | 1.0.5 |
| deltaww | infrasuite_device_master | < 1.0.5 | 1.0.5 |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Delta Electronics InfraSuite Device Master
cisa_ics·2023-03-21·CVSS 9.8
[CRITICAL] Delta Electronics InfraSuite Device Master
ICS Advisory
##
Delta Electronics InfraSuite Device Master
Release DateMarch 21, 2023
Alert CodeICSA-23-080-02
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Delta Electronics
- Equipment: InfraSuite Device Master
- Vulnerabilities: Deserialization of Untrusted Data, Improper Access Control, Exposed Dangerous Method or Function, Path Traversal, Improper Authentication, Command Injection, Incorrect Permission Assignment for Critical Resource, Missing Authentication for Critical Function
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to obtain access to files and credentials, escalate privileges, and remotely execute arbitrary code.
## 3.
GHSA
GHSA-jmg5-m2qm-2x4x: Delta Electronics InfraSuite Device Master versions prior to 1
ghsa_unreviewed·2023-03-27
CVE-2023-1138 [HIGH] GHSA-jmg5-m2qm-2x4x: Delta Electronics InfraSuite Device Master versions prior to 1
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2023-03-27
Published