CVE-2023-28002
published 2023-11-14CVE-2023-28002: An improper validation of integrity check value vulnerability [CWE-354] in FortiOS 7.2.0 through 7.2.3, 7.0.0 through 7.0.12, 6.4 all versions, 6.2 all…
PriorityP430medium6.7CVSS 3.1
AVLACLPRHUINSUCHIHAH
EPSS
0.17%
6.9th percentile
An improper validation of integrity check value vulnerability [CWE-354] in FortiOS 7.2.0 through 7.2.3, 7.0.0 through 7.0.12, 6.4 all versions, 6.2 all versions, 6.0 all versions and VMs may allow a local attacker with admin privileges to boot a malicious image on the device and bypass the filesystem integrity check in place.
Affected
11 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| fortinet | fortios | — | — |
| fortinet | fortios | 6.0.0 – 6.0.17 | — |
| fortinet | fortios | 6.2.0 – 6.2.15 | — |
| fortinet | fortios | 6.4.0 – 6.4.14 | — |
| fortinet | fortios | 7.0.0 – 7.0.12 | — |
| fortinet | fortios | 7.2.0 – 7.2.3 | — |
| fortinet | fortiproxy | — | — |
| fortinet | fortiproxy | 2.0.0 – 2.0.13 | — |
| fortinet | fortiproxy | 7.0.0 – 7.0.13 | — |
| fortinet | fortiproxy | 7.2.0 – 7.2.7 | — |
| fortinet | fortiproxy | 7.4.0 – 7.4.1 | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens RUGGEDCOM APE1808 with Fortigate NGFW Devices
cisa_ics·2024-03-14
Siemens RUGGEDCOM APE1808 with Fortigate NGFW Devices
ICS Advisory
##
Siemens RUGGEDCOM APE1808 with Fortigate NGFW Devices
Release DateMarch 14, 2024
Alert CodeICSA-24-074-11
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: RUGGEDCOM APE1808 devices
- Vulnerabilities: Improper Certificate Validation, Cleartext Transmission of Sensitive Information, Path Traversal, Exposure of Sensitive Information to an Unauthorized
Fortinet
Bypass of root file system integrity checks at boot time on VM
vendor_fortinet·2023-11-14·CVSS 6.4
CVE-2023-28002 [MEDIUM] CWE-354 Bypass of root file system integrity checks at boot time on VM
FG-IR-22-396: Bypass of root file system integrity checks at boot time on VM
An improper validation of integrity check value vulnerability [CWE-354] in FortiOS 7.2.0 through 7.2.3, 7.0.0 through 7.0.12, 6.4 all versions, 6.2 all versions, 6.0 all versions and VMs may allow a local attacker with admin privileges to boot a malicious image on the device and bypass the filesystem integrity check in place.
CVEs: CVE-2023-28002
CWEs: CWE-354
CVSS: 6.4 (medium)
Affected products: FortiOS, FortiProxy
GHSA
GHSA-m6ww-2p98-rfp9: An improper validation of integrity check value vulnerability [CWE-354] in FortiOS 7
ghsa_unreviewed·2023-11-14
CVE-2023-28002 [MEDIUM] CWE-354 GHSA-m6ww-2p98-rfp9: An improper validation of integrity check value vulnerability [CWE-354] in FortiOS 7
An improper validation of integrity check value vulnerability [CWE-354] in FortiOS 7.2.0 through 7.2.3, 7.0.0 through 7.0.12, 6.4 all versions, 6.2 all versions, 6.0 all versions and FortiProxy 7.2 all versions, 7.0 all versions, 2.0 all versions VMs may allow a local attacker with admin privileges to boot a malicious image on the device and bypass the filesystem integrity check in place.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2023-11-14
Published