CVE-2023-29053
published 2023-04-11CVE-2023-29053: A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of…
PriorityP337high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
EPSS
0.22%
12.1th percentile
A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Affected
4 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | jt_open | — | — |
| siemens | jt_open_toolkit | < 11.3.2.0 | 11.3.2.0 |
| siemens | jt_utilities | < 13.3.0.0 | 13.3.0.0 |
| siemens | jt_utilities | — | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-8rcf-44xg-7jxr: A vulnerability has been identified in JT Open (All versions < V11
ghsa_unreviewed·2023-04-11
CVE-2023-29053 [HIGH] CWE-125 GHSA-8rcf-44xg-7jxr: A vulnerability has been identified in JT Open (All versions < V11
A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
CISA ICS
Siemens JT Open and JT Utilities
cisa_ics·2023-04-13·CVSS 7.8
[HIGH] Siemens JT Open and JT Utilities
ICS Advisory
##
Siemens JT Open and JT Utilities
Release DateApril 13, 2023
Alert CodeICSA-23-103-02
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
## 1. EXECUTIVE SUMMARY
- CVSS v3 7.8
- ATTENTION: Low attack complexity
- Vendor: Siemens
- Equipment: JT Open and JT Utilities
- Vulnerability: Out-of-bounds Read
## 2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process.
## 3. TECHNICAL DETAILS
## 3.1 AFFEC