CVE-2023-41033
published 2023-09-12CVE-2023-41033: A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions <…
PriorityP339high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
EPSS
0.21%
10.7th percentile
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)
Affected
10 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | parasolid | >= 35.0 < 35.0.260 | 35.0.260 |
| siemens | parasolid | >= 35.1 < 35.1.246 | 35.1.246 |
| siemens | parasolid | >= 36.0 < 36.0.156 | 36.0.156 |
| siemens | parasolid_v35.0 | — | — |
| siemens | parasolid_v35.1 | — | — |
| siemens | parasolid_v36.0 | — | — |
| siemens | simcenter_femap | >= 2301.0 < 2301.0003 | 2301.0003 |
| siemens | simcenter_femap | >= 2306.0 < 2306.0001 | 2306.0001 |
| siemens | simcenter_femap_v2301 | — | — |
| siemens | simcenter_femap_v2306 | — | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-5pvr-hmqg-8283: A vulnerability has been identified in Parasolid V35
ghsa_unreviewed·2023-09-14
CVE-2023-41033 [HIGH] CWE-787 GHSA-5pvr-hmqg-8283: A vulnerability has been identified in Parasolid V35
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)
CISA ICS
Siemens Parasolid
cisa_ics·2023-09-14·CVSS 7.8
[HIGH] Siemens Parasolid
ICS Advisory
##
Siemens Parasolid
Release DateSeptember 14, 2023
Alert CodeICSA-23-257-02
## As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
## View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v3 7.8
- ATTENTION: Low attack complexity
- Vendor: Siemens
- Equipment: Parasolid
- Vulnerabilities: Out-of-bounds Write
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process.
## 3. TECHNICAL DETAILS
## 3.1 AFFECTED
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2023-09-12
Published