CVE-2023-43623
published 2023-10-10CVE-2023-43623: A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions < V5.4.0), Mendix Forgot Password (Mendix 7 compatible) (All…
PriorityP430medium5.3CVSS 3.1
AVNACLPRNUINSUCLINAN
EPSS
0.51%
39.5th percentile
A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions < V5.4.0), Mendix Forgot Password (Mendix 7 compatible) (All versions < V3.7.3), Mendix Forgot Password (Mendix 8 compatible) (All versions < V4.1.3), Mendix Forgot Password (Mendix 9 compatible) (All versions < V5.4.0). Applications using the affected module are vulnerable to user enumeration due to distinguishable responses. This could allow an unauthenticated remote attacker to determine if a user is valid or not, enabling a brute force attack with valid users.
Affected
6 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| mendix | forgot_password | < 3.7.3 | 3.7.3 |
| mendix | forgot_password | >= 4.0.0 < 4.1.3 | 4.1.3 |
| mendix | forgot_password | >= 5.0.0 < 5.4.0 | 5.4.0 |
| siemens | mendix_forgot_password | — | — |
| siemens | mendix_forgot_password | — | — |
| siemens | mendix_forgot_password | — | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens Mendix Forgot Password Module
cisa_ics·2023-10-12·CVSS 5.3
[MEDIUM] Siemens Mendix Forgot Password Module
ICS Advisory
##
Siemens Mendix Forgot Password Module
Release DateOctober 12, 2023
Alert CodeICSA-23-285-11
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v3 5.3
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: Mendix Forgot Password Module
- Vulnerability: Observable Discrepancy
## 2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to determine if a user
GHSA
GHSA-7953-vwv9-3rqv: A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions < V5
ghsa_unreviewed·2023-10-10
CVE-2023-43623 [MEDIUM] CWE-203 GHSA-7953-vwv9-3rqv: A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions < V5
A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions < V5.4.0), Mendix Forgot Password (Mendix 7 compatible) (All versions < V3.7.3), Mendix Forgot Password (Mendix 8 compatible) (All versions < V4.1.3), Mendix Forgot Password (Mendix 9 compatible) (All versions < V5.4.0). Applications using the affected module are vulnerable to user enumeration due to distinguishable responses. This could allow an unauthenticated remote attacker to determine if a user is valid or not, enabling a brute force attack with valid users.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2023-10-10
Published