CVE-2023-44086
published 2023-10-10CVE-2023-44086: A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions <…
PriorityP338high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
EPSS
0.22%
12.0th percentile
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
Affected
4 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | tecnomatix | >= 2201 < 2201.0009 | 2201.0009 |
| siemens | tecnomatix | >= 2302 < 2302.0003 | 2302.0003 |
| siemens | tecnomatix_plant_simulation_v2201 | — | — |
| siemens | tecnomatix_plant_simulation_v2302 | — | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-8qv8-ggmf-rmpp: A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201
ghsa_unreviewed·2023-10-10
CVE-2023-44086 [HIGH] CWE-125 GHSA-8qv8-ggmf-rmpp: A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CISA ICS
Siemens Tecnomatix Plant Simulation
cisa_ics·2023-10-12·CVSS 7.8
[HIGH] Siemens Tecnomatix Plant Simulation
ICS Advisory
##
Siemens Tecnomatix Plant Simulation
Release DateOctober 12, 2023
Alert CodeICSA-23-285-10
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v3 7.8
- ATTENTION: Low Attack Complexity
- Vendor: Siemens
- Equipment: Tecnomatix Plant Simulation
- Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to perform code execution after leading a user t
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2023-10-10
Published