CVE-2024-22186
published 2024-04-18CVE-2024-22186: The application suffers from a privilege escalation vulnerability. An attacker logged in as guest can escalate his privileges by poisoning the cookie to become…
PriorityP350high8.8CVSS 3.1
AVNACLPRLUINSUCHIHAH
EPSS
0.55%
41.8th percentile
The application suffers from a privilege escalation vulnerability. An
attacker logged in as guest can escalate his privileges by poisoning the
cookie to become administrator.
Affected
24 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| electrolink | compact_dab_transmitter | — | — |
| electrolink | compact_dab_transmitter | — | — |
| electrolink | compact_dab_transmitter | — | — |
| electrolink | compact_fm_transmitter | — | — |
| electrolink | compact_fm_transmitter | — | — |
| electrolink | compact_fm_transmitter | — | — |
| electrolink | compact_fm_transmitter | — | — |
| electrolink | digital_fm_transmitter | 15W – 40kW | — |
| electrolink | high_power_dab_transmitter | — | — |
| electrolink | high_power_dab_transmitter | — | — |
| electrolink | high_power_dab_transmitter | — | — |
| electrolink | high_power_dab_transmitter | — | — |
| electrolink | medium_dab_transmitter | — | — |
| electrolink | medium_dab_transmitter | — | — |
| electrolink | medium_dab_transmitter | — | — |
| electrolink | modular_fm_transmitter | — | — |
| electrolink | modular_fm_transmitter | — | — |
| electrolink | modular_fm_transmitter | — | — |
| electrolink | modular_fm_transmitter | — | — |
| electrolink | modular_fm_transmitter | — | — |
| electrolink | modular_fm_transmitter | — | — |
| electrolink | uhf_tv_transmitter | 10W – 5kW | — |
| electrolink | vhf_tv_transmitter | — | — |
| electrolink | vhf_tv_transmitter | — | — |
CVSS provenance
nvdv3.18.8HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
nvdv4.08.7HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Electrolink FM/DAB/TV Transmitter
cisa_ics·2024-04-16·CVSS 8.7
[HIGH] Electrolink FM/DAB/TV Transmitter
ICS Advisory
##
Electrolink FM/DAB/TV Transmitter
Release DateApril 16, 2024
Alert CodeICSA-24-107-02
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v3 8.8
- ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
- Vendor: Electrolink
- Equipment: FM/DAB/TV Transmitter
- Vulnerabilities: Authentication Bypass by Assumed-Immutable Data, Reliance on Cookies without Validation and Integrity Checking, Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to obtain full system access, keep the device from transmitting, escalate privileges, change credentials, and execute arbitrary code.
## 3. TECHNICAL DETAILS
GHSA
GHSA-7phh-j5x4-5979: The application suffers from a privilege escalation vulnerability
ghsa_unreviewed·2024-04-19
CVE-2024-22186 [HIGH] CWE-565 GHSA-7phh-j5x4-5979: The application suffers from a privilege escalation vulnerability
The application suffers from a privilege escalation vulnerability. An
attacker logged in as guest can escalate his privileges by poisoning the
cookie to become administrator.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2024-04-18
Published