CVE-2024-23803
published 2024-02-13CVE-2024-23803: A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The…
PriorityP339high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
EPSS
0.21%
10.8th percentile
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
Affected
4 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | tecnomatix_plant_simulation | — | — |
| siemens | tecnomatix_plant_simulation | >= 2302.0 < 2302.0007 | 2302.0007 |
| siemens | tecnomatix_plant_simulation_v2201 | < * | * |
| siemens | tecnomatix_plant_simulation_v2302 | < V2302.0007 | V2302.0007 |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-2569-97m4-w479: A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302
ghsa_unreviewed·2024-02-13
CVE-2024-23803 [HIGH] CWE-787 GHSA-2569-97m4-w479: A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
CISA ICS
Siemens Tecnomatix Plant Simulation
cisa_ics·2024-02-15·CVSS 7.8
[HIGH] Siemens Tecnomatix Plant Simulation
ICS Advisory
##
Siemens Tecnomatix Plant Simulation
Release DateFebruary 15, 2024
Alert CodeICSA-24-046-07
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v4 7.3
- ATTENTION: Low Attack Complexity
- Vendor: Siemens
- Equipment: Tecnomatix Plant Simulation
- Vulnerabilities: Out-of-bounds Write, Heap-based Buffer Overflow, Stack-based Buffer Overflow, NULL Pointer Dereference, Out-of-bounds Read
## 2. RISK EVALUATION
Successful exploitation of this vulne
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2024-02-13
Published