CVE-2024-2851
published 2024-03-24CVE-2024-2851: A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file…
PriorityP187critical9.8CVSS 3.1
AVNACLPRNUINSUCHIHAH
ITWVulnCheck KEV
Exploited in the wild
EPSS
4.01%
90.3th percentile
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected
4 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| tenda | ac15 | — | — |
| tenda | ac15 | — | — |
| tenda | ac15_firmware | — | — |
| tenda | ac15_firmware | — | — |
CVSS provenance
nvdv3.19.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv2.06.5MEDIUMAV:N/AC:L/Au:S/C:P/I:P/A:P
vulncheck9.8CRITICAL
CVEs like this are exactly what “Exploited This Week” covers.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-67h4-mrpp-g64j: A vulnerability was found in Tenda AC15 15
ghsa_unreviewed·2024-03-24
CVE-2024-2851 [MEDIUM] CWE-78 GHSA-67h4-mrpp-g64j: A vulnerability was found in Tenda AC15 15
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
VulnCheck
Tenda ac15_firmware Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulncheck·2024·CVSS 9.8
CVE-2024-2851 [CRITICAL] Tenda ac15_firmware Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Tenda ac15_firmware Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected: Tenda ac15_firmware
Required Action: Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations a
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.mdhttps://vuldb.com/?ctiid.257775https://vuldb.com/?id.257775https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/formSetSambaConf.mdhttps://vuldb.com/?ctiid.257775https://vuldb.com/?id.257775
2024-03-24
Published
Exploited in the wild