CVE-2024-32056
published 2024-07-09CVE-2024-32056: A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an…
PriorityP338high7.8CVSS 3.1
AVLACLPRNUIRSUCHIHAH
EPSS
0.17%
6.9th percentile
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | simcenter_femap | < V2406 | V2406 |
| siemens | simcenter_femap | < 2406.0 | 2406.0 |
CVSS provenance
nvdv3.17.8HIGHCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
nvdv4.07.3HIGHCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens Simcenter Femap
cisa_ics·2024-07-11·CVSS 7.3
[HIGH] Siemens Simcenter Femap
ICS Advisory
##
Siemens Simcenter Femap
Release DateJuly 11, 2024
Alert CodeICSA-24-193-04
Related topics:
Industrial Control System Vulnerabilities, Industrial Control Systems
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v4 7.3
- ATTENTION: Low Attack Complexity
- Vendor: Siemens
- Equipment: Simcenter Femap
- Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write, Type Confusion, Improper Restriction of Operations within the Bounds of a Memory B
GHSA
GHSA-p4cq-6pr4-7mqj: A vulnerability has been identified in Simcenter Femap (All versions < V2406)
ghsa_unreviewed·2024-07-09
CVE-2024-32056 [HIGH] CWE-787 GHSA-p4cq-6pr4-7mqj: A vulnerability has been identified in Simcenter Femap (All versions < V2406)
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS part file. This could allow an attacker to execute code in the context of the current process.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2024-07-09
Published