CVE-2024-45558
published 2025-01-06CVE-2024-45558: Transient DOS can occur when the driver parses the per STA profile IE and tries to access the EXTN element ID without checking the IE length.
PriorityP336high7.5CVSS 3.1
AVNACLPRNUINSUCNINAH
EPSS
0.35%
27.2th percentile
Transient DOS can occur when the driver parses the per STA profile IE and tries to access the EXTN element ID without checking the IE length.
Affected
184 ranges· showing 25
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| android | — | — | |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
| qualcomm_inc | snapdragon | — | — |
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
Android
CVE-2024-45558: WLAN
vendor_android·2025-01-01·CVSS 7.5
CVE-2024-45558 [HIGH] CVE-2024-45558: WLAN
Android Security Bulletin 2025-01-01
CVE: CVE-2024-45558
Severity: HIGH
Component: WLAN
References: A-372002616
QC-CR#3852338
GHSA
GHSA-jj76-44fx-5g9w: Transient DOS can occur when the driver parses the per STA profile IE and tries to access the EXTN element ID without checking the IE length
ghsa_unreviewed·2025-01-06
CVE-2024-45558 [HIGH] CWE-125 GHSA-jj76-44fx-5g9w: Transient DOS can occur when the driver parses the per STA profile IE and tries to access the EXTN element ID without checking the IE length
Transient DOS can occur when the driver parses the per STA profile IE and tries to access the EXTN element ID without checking the IE length.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2025-01-06
Published