CVE-2024-47562
published 2024-10-08CVE-2024-47562: A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements…
PriorityP349high8.8CVSS 3.1
AVLACLPRLUINSCCHIHAH
EPSS
0.27%
18.4th percentile
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command.
This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| siemens | sinec_security_monitor | < V4.9.0 | V4.9.0 |
| siemens | sinec_security_monitor | < 4.9.0 | 4.9.0 |
CVSS provenance
nvdv3.18.8HIGHCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
nvdv4.09.3CRITICALCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Siemens SINEC Security Monitor
cisa_ics·2024-10-10·CVSS 9.4
[CRITICAL] Siemens SINEC Security Monitor
ICS Advisory
##
Siemens SINEC Security Monitor
Release DateOctober 10, 2024
Alert CodeICSA-24-284-06
Related topics:
Industrial Control System Vulnerabilities, Industrial Control Systems
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v4 9.4
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: SINEC Security Monitor
- Vulnerabilities: Argument Injection, Command Injection, Path Traversal, Permissive List of Allowed Inp
GHSA
GHSA-hq54-fc5j-p5hh: A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4
ghsa_unreviewed·2024-10-08
CVE-2024-47562 [CRITICAL] CWE-77 GHSA-hq54-fc5j-p5hh: A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4
A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command.
This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2024-10-08
Published