CVE-2025-0497
published 2025-01-30CVE-2025-0497: A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to…
PriorityP353critical9.8CVSS 3.1
AVNACLPRNUINSUCHIHAH
EPSS
0.32%
23.2th percentile
A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages.
Affected
2 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| rockwell_automation | factorytalk_assetcentre | — | — |
| rockwellautomation | factorytalk_assetcentre | < 15.00.01 | 15.00.01 |
CVSS provenance
nvdv3.19.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvdv4.07.3HIGHCVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-6cxx-5fj7-8mm3: A data exposure vulnerability exists in all versions prior to V15
ghsa_unreviewed·2025-01-30
CVE-2025-0497 [HIGH] CWE-522 GHSA-6cxx-5fj7-8mm3: A data exposure vulnerability exists in all versions prior to V15
A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages.
CISA ICS
Rockwell Automation FactoryTalk AssetCentre
cisa_ics·2025-01-30·CVSS 9.3
[CRITICAL] Rockwell Automation FactoryTalk AssetCentre
ICS Advisory
##
Rockwell Automation FactoryTalk AssetCentre
Release DateJanuary 30, 2025
Alert CodeICSA-25-030-05
Related topics:
Industrial Control System Vulnerabilities, Industrial Control Systems
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v4 9.3
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Rockwell Automation
- Equipment: FactoryTalk AssetCentre
- Vulnerabilities: Inadequate Encryption Strength, Insufficiently Protected Credentials
## 2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to extract passwords, access, credentials, or impersonate other users.
## 3. TECHNICAL DETAILS
## 3.1 AFFECTED PRODUCTS
The following versions of Rockwell Automation FactoryTalk AssetCentre are affected:
-
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2025-01-30
Published