CVE-2025-50124
published 2025-07-11CVE-2025-50124: A CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the server is accessed by a privileged account via a…
PriorityP433high7.2CVSS 4.0
AVPACHATPPRHUINVCHVIHVAHSCHSILSAHEXCRXIRXARXMAVXMACXMATXMPRXMUIXMVCXMVIXMVAXMSCXMSIXMSAXSXAUXRXVXREXUX
EPSS
0.18%
8.0th percentile
A
CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the
server is accessed by a privileged account via a console and through exploitation of a setup script.
Affected
3 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| msrc | azl3_kernel_6.6.57.1-7_on_azure_linux_3.0 | — | — |
| msrc | azl3_kernel_6.6.64.2-1_on_azure_linux_3.0 | — | — |
| schneider_electric | ecostruxure_it_data_center_expert | 8.3 – Prior to | — |
CVSS provenance
nvdv4.07.2HIGHCVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vendor_msrc7.8HIGH
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
CISA ICS
Schneider Electric EcoStruxture IT Data Center Expert
cisa_ics·2025-07-22·CVSS 9.5
[CRITICAL] Schneider Electric EcoStruxture IT Data Center Expert
ICS Advisory
##
Schneider Electric EcoStruxture IT Data Center Expert
Release DateJuly 22, 2025
Alert CodeICSA-25-203-06
Related topics:
Industrial Control System Vulnerabilities, Industrial Control Systems
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v4 9.5
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Schneider Electric
- Equipment: EcoStruxure IT Data Center Expert
- Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Insufficient Entropy, Improper Control of Generation of Code ('Code Injection'), Server-Side Request Forgery (SSRF), Improper Privilege Management, and Improper Restriction of XML External Entity Reference
## 2. RISK EVALUATION
Successful exploitation of these vuln
Microsoft
Bluetooth: ISO: Fix UAF on iso_sock_timeout
vendor_msrc·2024-11-12·CVSS 7.8
CVE-2024-50124 [HIGH] CWE-416 Bluetooth: ISO: Fix UAF on iso_sock_timeout
Bluetooth: ISO: Fix UAF on iso_sock_timeout
FAQ: Is Azure Linux the only Microsoft product that includes this open-source library and is therefore potentially affected by this vulnerability?
One of the main benefits to our customers who choose to use the Azure Linux distro is the commitment to keep it up to date with the most recent and most secure versions of the open source libraries with which the distro is composed. Microsoft is committed to transparency in this work which is why we began publishing CSAF/VEX in October 2025. See this blog post for more information. If impact to additional products is identified, we will update the CVE to reflect this.
Mariner: Mariner
Linux: Linux
Customer Action Required: Yes
Remediation: CBL-Mariner Releases
Reference: https://learn.microsoft.c
GHSA
GHSA-x2h5-r7cj-6jqv: CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the
server is accessed by a privileged account
ghsa_unreviewed·2025-07-11
CVE-2025-50124 [HIGH] CWE-269 GHSA-x2h5-r7cj-6jqv: CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the
server is accessed by a privileged account
CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the
server is accessed by a privileged account via a console and through exploitation of a setup script.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2025-07-11
Published