CVE-2025-54754
published 2025-09-18CVE-2025-54754: An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available…
PriorityP345high8CVSS 3.1
AVAACLPRNUIRSUCHIHAH
EPSS
0.23%
13.5th percentile
An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly available software. This password can then be used to decrypt
sensitive network traffic, affecting the Cognex device.
Affected
5 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| cognex | in-sight_2000_series | 5.x – 6.5.1 | — |
| cognex | in-sight_7000_series | 5.x – 6.5.1 | — |
| cognex | in-sight_8000_series | 5.x – 6.5.1 | — |
| cognex | in-sight_9000_series | 5.x – 6.5.1 | — |
| cognex | in-sight_explorer | 5.x – 6.5.1 | — |
CVSS provenance
nvdv3.18.0HIGHCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
nvdv4.08.6HIGHCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
GHSA-x8j7-fjhf-36jc: An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly availa
ghsa_unreviewed·2025-09-18
CVE-2025-54754 [HIGH] CWE-259 GHSA-x8j7-fjhf-36jc: An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly availa
An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly available software. This password can then be used to decrypt
sensitive network traffic, affecting the Cognex device.
CISA ICS
Cognex In-Sight Explorer and In-Sight Camera Firmware
cisa_ics·2025-09-18·CVSS 8.0
[HIGH] Cognex In-Sight Explorer and In-Sight Camera Firmware
ICS Advisory
##
Cognex In-Sight Explorer and In-Sight Camera Firmware
Release DateSeptember 18, 2025
Alert CodeICSA-25-261-06
Related topics:
Industrial Control System Vulnerabilities, Industrial Control Systems
View CSAF
## 1. EXECUTIVE SUMMARY
- CVSS v4 8.6
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Cognex
- Equipment: In-Sight Explorer, In-Sight Camera Firmware
- Vulnerabilities: Use of Hard-coded Password, Cleartext Transmission of Sensitive Information, Incorrect Default Permissions, Improper Restriction of Excessive Authentication Attempts, Incorrect Permission Assignment for Critical Resource, Authentication Bypass by Capture-replay, Client-Side Enforcement of Server-Side Security
## 2. RISK EVALUATION
Successful exploitati
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2025-09-18
Published