CVE-2026-10164
published 2026-05-31CVE-2026-10164: A vulnerability was found in Edimax BR-6478AC 1.23. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request…
PriorityP264high8.8CVSS 3.1
AVNACLPRLUINSUCHIHAH
EPSS
0.46%
36.7th percentile
A vulnerability was found in Edimax BR-6478AC 1.23. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. The manipulation of the argument ShareName/SelectName results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.
Affected
1 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| edimax | br-6478ac | — | — |
CVSS provenance
nvdv3.18.8HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
nvdv4.07.4HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
nvdv2.09.0CRITICALAV:N/AC:L/Au:S/C:C/I:C/A:C
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
A vulnerability was found in Edimax BR-6478AC 1.23.
ghsa_unreviewed·2026-05-31
CVE-2026-10164 [HIGH] CWE-119 A vulnerability was found in Edimax BR-6478AC 1.23.
A vulnerability was found in Edimax BR-6478AC 1.23. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. The manipulation of the argument ShareName/SelectName results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.
VulDB
Edimax BR-6478AC 1.23 POST Request /goform/formUSBFolder ShareName/SelectName buffer overflow
vuldb·2026-05-30
CVE-2026-10164 [CRITICAL] Edimax BR-6478AC 1.23 POST Request /goform/formUSBFolder ShareName/SelectName buffer overflow
A vulnerability classified as critical was found in Edimax BR-6478AC 1.23. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. The manipulation of the argument ShareName/SelectName results in buffer overflow.
This vulnerability is identified as CVE-2026-10164. The attack can be executed remotely. Additionally, an exploit exists.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2026-05-31
Published