CVE-2026-13583
published 2026-06-29CVE-2026-13583: A vulnerability has been found in Edimax EW-7478APC 1.04. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST…
PriorityP265high8.8CVSS 3.1
AVNACLPRLUINSUCHIHAH
EPSS
0.45%
35.6th percentile
A vulnerability has been found in Edimax EW-7478APC 1.04. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. Such manipulation of the argument ShareName/SelectName leads to buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Affected
1 ranges
| Vendor | Product | Version range | Fixed in |
|---|---|---|---|
| edimax | ew-7478apc | — | — |
CVSS provenance
nvdv3.18.8HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
nvdv4.07.4HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
nvdv2.09.0CRITICALAV:N/AC:L/Au:S/C:C/I:C/A:C
Stop checking back — get the weekly exploitation signal.
Every Monday: what got weaponized or added to CISA KEV in the last seven days — each CVE cross-linked to its PoC, Nuclei template, and detection rule. Free, one email a week, unsubscribe in one click.
GHSA
A vulnerability has been found in Edimax EW-7478APC 1.04.
ghsa_unreviewed·2026-06-29
CVE-2026-13583 [HIGH] CWE-119 A vulnerability has been found in Edimax EW-7478APC 1.04.
A vulnerability has been found in Edimax EW-7478APC 1.04. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. Such manipulation of the argument ShareName/SelectName leads to buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
VulDB
Edimax EW-7478APC 1.04 POST Request /goform/formUSBFolder ShareName/SelectName buffer overflow
vuldb·2026-06-29
CVE-2026-13583 [CRITICAL] Edimax EW-7478APC 1.04 POST Request /goform/formUSBFolder ShareName/SelectName buffer overflow
A vulnerability was found in Edimax EW-7478APC 1.04 and classified as critical. Impacted is the function formUSBFolder of the file /goform/formUSBFolder of the component POST Request Handler. Such manipulation of the argument ShareName/SelectName leads to buffer overflow.
This vulnerability is listed as CVE-2026-13583. The attack may be performed from remote. In addition, an exploit is available.
The vendor was contacted early about this disclosure but did not respond in any way.
No detection rules found.
No public exploits indexed.
No writeups or analysis indexed.
2026-06-29
Published