Dlink Dir-823X Firmware vulnerabilities
38 known vulnerabilities affecting dlink/dir-823x_firmware.
Total CVEs
38
CISA KEV
1
actively exploited
Public exploits
1
Exploited in wild
2
Severity breakdown
CRITICAL7HIGH29MEDIUM2
Vulnerabilities
Page 1 of 2
CVE-2025-29635P1HIGHCVSS 7.2KEVPoCv240126v2408022025-03-25
CVE-2025-29635 [HIGH] CWE-77 CVE-2025-29635: A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker
A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /goform/set_prohibiting via the corresponding function, triggering remote command execution.
nvd
CVE-2026-1125P1CRITICALCVSS 9.8Exploitedv2501262026-01-18
CVE-2026-1125 [CRITICAL] CWE-74 CVE-2026-1125: A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub
A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_wifidog_settings. Executing a manipulation of the argument wd_enable can lead to command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
nvd
CVE-2025-10401P2HIGHCVSS 8.8≤ 2504162025-09-14
CVE-2025-10401 [HIGH] CWE-74 CVE-2025-10401: A vulnerability was detected in D-Link DIR-823x up to 250416. The affected element is an unknown fun
A vulnerability was detected in D-Link DIR-823x up to 250416. The affected element is an unknown function of the file /goform/diag_ping. Performing manipulation of the argument target_addr results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.
nvd
CVE-2025-10814P2HIGHCVSS 8.8v240126v240802+1 more2025-09-22
CVE-2025-10814 [HIGH] CWE-74 CVE-2025-10814: A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerabili
A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.
nvd
CVE-2025-11098P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11098 [HIGH] CWE-74 CVE-2025-11098: A vulnerability was found in D-Link DIR-823X 250416. The affected element is an unknown function of
A vulnerability was found in D-Link DIR-823X 250416. The affected element is an unknown function of the file /goform/set_wifi_blacklists. The manipulation of the argument macList results in command injection. The attack may be performed from remote. The exploit has been made public and could be used.
nvd
CVE-2025-10123P2CRITICALCVSS 9.8≤ 2504162025-09-09
CVE-2025-10123 [CRITICAL] CWE-74 CVE-2025-10123: A vulnerability was determined in D-Link DIR-823X up to 250416. Affected by this vulnerability is th
A vulnerability was determined in D-Link DIR-823X up to 250416. Affected by this vulnerability is the function sub_415028 of the file /goform/set_static_leases. Executing manipulation of the argument Hostname can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
nvd
CVE-2025-11092P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11092 [HIGH] CWE-74 CVE-2025-11092: A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub
A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_switch_settings. This manipulation of the argument port causes command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited.
nvd
CVE-2025-11097P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11097 [HIGH] CWE-74 CVE-2025-11097: A vulnerability has been found in D-Link DIR-823X 250416. Impacted is an unknown function of the fil
A vulnerability has been found in D-Link DIR-823X 250416. Impacted is an unknown function of the file /goform/set_device_name. The manipulation of the argument mac leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
nvd
CVE-2026-1544P2HIGHCVSS 8.8v2504162026-01-28
CVE-2026-1544 [HIGH] CWE-77 CVE-2026-1544: A security flaw has been discovered in D-Link DIR-823X 250416. Impacted is the function sub_41E2A0 o
A security flaw has been discovered in D-Link DIR-823X 250416. Impacted is the function sub_41E2A0 of the file /goform/set_mode. Performing a manipulation of the argument lan_gateway results in os command injection. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. This vulnerabili
nvd
CVE-2025-10634P2HIGHCVSS 8.8v240126v240802+1 more2025-09-18
CVE-2025-10634 [HIGH] CWE-74 CVE-2025-10634: A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the
A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the function sub_412E7C of the file /usr/sbin/goahead of the component Environment Variable Handler. This manipulation of the argument terminal_addr/server_ip/server_port causes command injection. The attack can be initiated remotely. The exploit has been mad
nvd
CVE-2025-11100P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11100 [HIGH] CWE-74 CVE-2025-11100: A vulnerability was identified in D-Link DIR-823X 250416. This affects the function uci_set of the f
A vulnerability was identified in D-Link DIR-823X 250416. This affects the function uci_set of the file /goform/set_wifi_blacklists. Such manipulation leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used.
nvd
CVE-2025-11099P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11099 [HIGH] CWE-74 CVE-2025-11099: A vulnerability was determined in D-Link DIR-823X 250416. The impacted element is the function uci_d
A vulnerability was determined in D-Link DIR-823X 250416. The impacted element is the function uci_del of the file /goform/delete_prohibiting. This manipulation of the argument delvalue causes command injection. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
nvd
CVE-2025-11095P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11095 [HIGH] CWE-74 CVE-2025-11095: A vulnerability was detected in D-Link DIR-823X 250416. This vulnerability affects unknown code of t
A vulnerability was detected in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/delete_offline_device. Performing manipulation of the argument delvalue results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.
nvd
CVE-2025-11096P2HIGHCVSS 8.8v2504162025-09-28
CVE-2025-11096 [HIGH] CWE-74 CVE-2025-11096: A flaw has been found in D-Link DIR-823X 250416. This issue affects some unknown processing of the f
A flaw has been found in D-Link DIR-823X 250416. This issue affects some unknown processing of the file /goform/diag_traceroute. Executing manipulation of the argument target_addr can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used.
nvd
CVE-2026-2063P2HIGHCVSS 7.2v2504162026-02-06
CVE-2026-2063 [HIGH] CWE-77 CVE-2026-2063: A security flaw has been discovered in D-Link DIR-823X 250416. This vulnerability affects unknown co
A security flaw has been discovered in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/set_ac_server of the component Web Management Interface. The manipulation of the argument ac_server results in os command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for
nvd
CVE-2026-2210P2HIGHCVSS 7.2v2504162026-02-09
CVE-2026-2210 [HIGH] CWE-77 CVE-2026-2210: A vulnerability has been found in D-Link DIR-823X 250416. This affects the function sub_4211C8 of th
A vulnerability has been found in D-Link DIR-823X 250416. This affects the function sub_4211C8 of the file /goform/set_filtering. Such manipulation leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
nvd
CVE-2026-2081P2HIGHCVSS 7.2v2504162026-02-07
CVE-2026-2081 [HIGH] CWE-77 CVE-2026-2081: A vulnerability was determined in D-Link DIR-823X 250416. The affected element is an unknown functio
A vulnerability was determined in D-Link DIR-823X 250416. The affected element is an unknown function of the file /goform/set_password. This manipulation of the argument http_passwd causes os command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
nvd
CVE-2026-2155P2HIGHCVSS 7.2v2504162026-02-08
CVE-2026-2155 [HIGH] CWE-77 CVE-2026-2155: A security flaw has been discovered in D-Link DIR-823X 250416. The affected element is the function
A security flaw has been discovered in D-Link DIR-823X 250416. The affected element is the function sub_4208A0 of the file /goform/set_dmz of the component Configuration Handler. The manipulation of the argument dmz_host/dmz_enable results in os command injection. The attack can be executed remotely. The exploit has been released to the public and may be
nvd
CVE-2026-2142P2HIGHCVSS 7.2v2504162026-02-08
CVE-2026-2142 [HIGH] CWE-77 CVE-2026-2142: A weakness has been identified in D-Link DIR-823X 250416. This vulnerability affects the function su
A weakness has been identified in D-Link DIR-823X 250416. This vulnerability affects the function sub_420688 of the file /goform/set_qos. Executing a manipulation can lead to os command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
nvd
CVE-2026-2129P2HIGHCVSS 7.2v2504162026-02-08
CVE-2026-2129 [HIGH] CWE-77 CVE-2026-2129: A vulnerability was found in D-Link DIR-823X 250416. Affected by this issue is some unknown function
A vulnerability was found in D-Link DIR-823X 250416. Affected by this issue is some unknown functionality of the file /goform/set_ac_status. Performing a manipulation of the argument ac_ipaddr/ac_ipstatus/ap_randtime results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used.
nvd
1 / 2Next →