cbcvebase.

F5 Big-Ip Ddos Hybrid Defender vulnerabilities

160 known vulnerabilities affecting f5/big-ip_ddos_hybrid_defender.

Total CVEs
160
CISA KEV
6
actively exploited
Public exploits
4
Exploited in wild
6
Severity breakdown
CRITICAL9HIGH93MEDIUM57LOW1

Vulnerabilities

Page 2 of 8
CVE-2025-61958P3HIGHCVSS 8.7≥ 15.1.0, < 15.1.10.8≥ 16.1.0, < 16.1.6.1+2 more2025-10-15
CVE-2025-61958 [HIGH] CWE-250 CVE-2025-61958: A vulnerability exists in the iHealth command that may allow an authenticated attacker with at least A vulnerability exists in the iHealth command that may allow an authenticated attacker with at least a resource administrator role to bypass tmsh restrictions and gain access to a bash shell. For BIG-IP systems running in Appliance mode, a successful exploit can allow the attacker to cross a security boundary. Note: Software versions which have reache
nvd
CVE-2026-34176P3HIGHCVSS 8.7≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-34176 [HIGH] CWE-78 CVE-2026-34176: When running in Appliance mode, an authenticated remote command injection vulnerability exists in an When running in Appliance mode, an authenticated remote command injection vulnerability exists in an undisclosed iControl REST endpoint. A successful exploit can allow the attacker to cross a security boundary. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2026-32673P3HIGHCVSS 8.7≥ 17.1., ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-32673 [HIGH] CWE-250 CVE-2026-32673: A vulnerability exists in BIG-IP scripted monitors that may allow an authenticated attacker with the A vulnerability exists in BIG-IP scripted monitors that may allow an authenticated attacker with the Resource Administrator or Administrator role to execute arbitrary system commands with higher privileges. In appliance mode deployments, a successful exploit can allow the attacker to cross a security boundary. Note: Software versions which have reache
nvd
CVE-2021-22990P3HIGHCVSS 7.2≥ 11.6.1, < 11.6.5.3≥ 12.1.0, < 12.1.5.3+4 more2021-03-31
CVE-2021-22990 [HIGH] CVE-2021-22990: On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x befo On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, 12.1.x before 12.1.5.3, and 11.6.x before 11.6.5.3, on systems with Advanced WAF or BIG-IP ASM provisioned, the Traffic Management User Interface (TMUI), also referred to as the Configuration utility, has an authenticated remote command execution v
nvd
CVE-2026-41953P3HIGHCVSS 8.7≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-41953 [HIGH] CWE-77 CVE-2026-41953: A vulnerability exists in BIG-IP systems where a highly privileged, authenticated attacker with at l A vulnerability exists in BIG-IP systems where a highly privileged, authenticated attacker with at least the Resource Administrator role can modify configuration objects resulting in privilege escalation. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2026-40631P3HIGHCVSS 8.7≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-40631 [HIGH] CWE-552 CVE-2026-40631: An authenticated attacker with the Resource Administrator or Administrator role can modify configura An authenticated attacker with the Resource Administrator or Administrator role can modify configuration objects through iControl SOAP resulting in privilege escalation. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2026-32643P3HIGHCVSS 8.7≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-32643 [HIGH] CWE-250 CVE-2026-32643: A vulnerability exists in BIG-IP and BIG-IQ systems where a highly privileged, authenticated attacke A vulnerability exists in BIG-IP and BIG-IQ systems where a highly privileged, authenticated attacker with at least the Certificate Manager role can modify configuration objects that allow running arbitrary commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2026-42406P3HIGHCVSS 8.7≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-42406 [HIGH] CWE-267 CVE-2026-42406: A vulnerability exists in BIG-IP and BIG-IQ systems where a highly privileged, authenticated attacke A vulnerability exists in BIG-IP and BIG-IQ systems where a highly privileged, authenticated attacker with at least the Certificate Manager role can modify configuration objects that allow running arbitrary commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2025-53868P3HIGHCVSS 8.7≥ 15.1.0, < 15.1.10.8≥ 16.1.0, < 16.1.6.1+2 more2025-10-15
CVE-2025-53868 [HIGH] CWE-78 CVE-2025-53868: When running in Appliance mode, a highly privileged authenticated attacker with access to SCP and SF When running in Appliance mode, a highly privileged authenticated attacker with access to SCP and SFTP may be able to bypass Appliance mode restrictions using undisclosed commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2026-40698P3HIGHCVSS 8.7≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-40698 [HIGH] CWE-77 CVE-2026-40698: A vulnerability exists in BIG-IP and BIG-IQ systems where a highly privileged, authenticated attacke A vulnerability exists in BIG-IP and BIG-IQ systems where a highly privileged, authenticated attacker with at least the Resource Administrator role can create SNMP configuration objects through iControl REST or the TMOS shell (tmsh) resulting in privilege escalation. Note: Software versions which have reached End of Technical Support (EoTS) are not eva
nvd
CVE-2026-39459P3HIGHCVSS 7.2≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-39459 [HIGH] CWE-272 CVE-2026-39459: A vulnerability exists in iControl REST and the TMOS Shell (tmsh) where a highly privileged, authent A vulnerability exists in iControl REST and the TMOS Shell (tmsh) where a highly privileged, authenticated attacker with at least the Manager role can create configuration objects that allow running arbitrary commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2023-43746P3HIGHCVSS 8.7≥ 13.1.0, ≤ 14.1.5≥ 15.1.0, < 15.1.9+1 more2023-10-10
CVE-2023-43746 [HIGH] CWE-267 CVE-2023-43746: When running in Appliance mode, an authenticated user assigned the Administrator role may be able t When running in Appliance mode, an authenticated user assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing BIG-IP external monitor on a BIG-IP system. A successful exploit can allow the attacker to cross a security boundary. Note: Software versions which have reached End of Technical Support (EoTS) are not evalua
nvd
CVE-2026-39455P3HIGHCVSS 7.5≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-39455 [HIGH] CWE-772 CVE-2026-39455: When the BIG-IP Configuration utility is configured to use Lightweight Directory Access Protocol (LD When the BIG-IP Configuration utility is configured to use Lightweight Directory Access Protocol (LDAP) authentication, undisclosed traffic can cause the httpd process to exhaust the available file descriptors. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2021-22974P3HIGHCVSS 7.5≥ 13.1.0, < 13.1.3.6≥ 14.1.0, < 14.1.3.1+2 more2021-02-12
CVE-2021-22974 [HIGH] CVE-2021-22974: On BIG-IP version 16.0.x before 16.0.1.1, 15.1.x before 15.1.2, 14.1.x before 14.1.3.1, and 13.1.x b On BIG-IP version 16.0.x before 16.0.1.1, 15.1.x before 15.1.2, 14.1.x before 14.1.3.1, and 13.1.x before 13.1.3.6 and all versions of BIG-IQ 7.x and 6.x, an authenticated attacker with access to iControl REST over the control plane may be able to take advantage of a race condition to execute commands with an elevated privilege level. This vulnerability is du
nvd
CVE-2026-41218P3HIGHCVSS 7.5≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-41218 [HIGH] CWE-416 CVE-2026-41218: When BIG-IP PEM iRules are configured on a virtual server (iRules using commands starting with CLASS When BIG-IP PEM iRules are configured on a virtual server (iRules using commands starting with CLASSIFICATION::, CLASSIFY::, PEM::, PSC::, and the urlcatquery command), undisclosed traffic can cause the Traffic Management Microkernel (TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2025-46706P3HIGHCVSS 7.5≥ 16.1.0, < 16.1.6≥ 17.1.0, < 17.1.2.22025-10-15
CVE-2025-46706 [HIGH] CWE-770 CVE-2025-46706: When an iRule containing the HTTP::respond command is configured on a virtual server, undisclosed re When an iRule containing the HTTP::respond command is configured on a virtual server, undisclosed requests can cause an increase in memory resource utilization. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2021-23013P3HIGHCVSS 7.5≥ 12.1.0, < 12.1.5.3≥ 13.1.0, < 13.1.4+3 more2021-05-10
CVE-2021-23013 [HIGH] CVE-2021-23013: On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.3, 14.1.x before 14.1.4, 13.1.x before On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.3, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, and 12.1.x before 12.1.5.3, the Traffic Management Microkernel (TMM) may stop responding when processing Stream Control Transmission Protocol (SCTP) traffic under certain conditions. This vulnerability affects TMM by way of a virtual server configure
nvd
CVE-2025-48008P3HIGHCVSS 7.5≥ 15.1.0, < 15.1.10.8≥ 16.1.0, < 16.1.62025-10-15
CVE-2025-48008 [HIGH] CWE-416 CVE-2025-48008: When a TCP profile with Multipath TCP (MPTCP) enabled is configured on a virtual server, undisclosed When a TCP profile with Multipath TCP (MPTCP) enabled is configured on a virtual server, undisclosed traffic along with conditions beyond the attacker's control can cause the Traffic Management Microkernel (TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
nvd
CVE-2026-41217P3HIGHCVSS 7.9≥ 17.1.0, ≤ 17.1.3≥ 17.5.0, ≤ 17.5.1+2 more2026-05-13
CVE-2026-41217 [HIGH] CWE-732 CVE-2026-41217: A vulnerability exists in an undisclosed BIG-IP TMOS Shell (tmsh) command that may allow an authenti A vulnerability exists in an undisclosed BIG-IP TMOS Shell (tmsh) command that may allow an authenticated attacker with resource administrator or administrator role to execute arbitrary system commands with higher privileges. In Appliance mode deployments, a successful exploit can allow the attacker to cross a security boundary. Note: Software versio
nvd
CVE-2023-22323P3HIGHCVSS 7.5≥ 13.1.0, ≤ 13.1.5≥ 14.1.0, < 14.1.5.3+2 more2023-02-01
CVE-2023-22323 [HIGH] CWE-770 CVE-2023-22323: In BIP-IP versions 17.0.x before 17.0.0.2, 16.1.x before 16.1.3.3, 15.1.x before 15.1.8.1, 14.1.x be In BIP-IP versions 17.0.x before 17.0.0.2, 16.1.x before 16.1.3.3, 15.1.x before 15.1.8.1, 14.1.x before 14.1.5.3, and all versions of 13.1.x, when OCSP authentication profile is configured on a virtual server, undisclosed requests can cause an increase in CPU resource utilization. Note: Software versions which have reached End of Technical Support (E
nvd