CVE-2021-32988P2CRITICALCVSS 9.8≤ 3.302021-06-29
CVE-2021-32988 [CRITICAL] CWE-787 CVE-2021-32988: FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds write, whic FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.
nvd
CVE-2021-32992P3CRITICALCVSS 9.8≤ 3.302021-06-29
CVE-2021-32992 [CRITICAL] CWE-119 CVE-2021-32992: FATEK Automation WinProladder Versions 3.30 and prior do not properly restrict operations within the FATEK Automation WinProladder Versions 3.30 and prior do not properly restrict operations within the bounds of a memory buffer, which may allow an attacker to execute arbitrary code.
nvd
CVE-2021-32990P3CRITICALCVSS 9.8≤ 3.302021-06-29
CVE-2021-32990 [CRITICAL] CWE-125 CVE-2021-32990: FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds read, which FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
nvd
CVE-2021-43554P3HIGHCVSS 7.8≤ 3.30_245182021-12-28
CVE-2021-43554 [HIGH] CWE-787 CVE-2021-43554: FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to an out-of-bounds write while proc FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
nvd
CVE-2021-43556P3HIGHCVSS 7.8≤ 3.30_245182021-12-28
CVE-2021-43556 [HIGH] CWE-121 CVE-2021-43556: FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to a stack-based buffer overflow whi FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code.
nvd
CVE-2021-38430P3HIGHCVSS 7.8≤ 3.302021-10-18
CVE-2021-38430 [HIGH] CWE-121 CVE-2021-38430: FATEK Automation WinProladder versions 3.30 and prior proper validation of user-supplied data when p FATEK Automation WinProladder versions 3.30 and prior proper validation of user-supplied data when parsing project files, which could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code.
nvd
CVE-2021-38426P3HIGHCVSS 7.8≤ 3.302021-10-18
CVE-2021-38426 [HIGH] CWE-787 CVE-2021-38426: FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code.
nvd
CVE-2021-38436P3HIGHCVSS 7.8≤ 3.302021-10-18
CVE-2021-38436 [HIGH] CWE-119 CVE-2021-38436: FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a memory-corruption condition. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
nvd
CVE-2021-27486P3HIGHCVSS 7.8≤ 3.302021-04-12
CVE-2021-27486 [HIGH] CWE-191 CVE-2021-27486: FATEK Automation WinProladder Versions 3.30 and prior is vulnerable to an integer underflow, which m FATEK Automation WinProladder Versions 3.30 and prior is vulnerable to an integer underflow, which may cause an out-of-bounds write and allow an attacker to execute arbitrary code.
nvd
CVE-2021-38434P3HIGHCVSS 7.8≤ 3.302021-10-18
CVE-2021-38434 [HIGH] CWE-194 CVE-2021-38434: FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an unexpected sign extension. An attacker could leverage this vulnerability to execute arbitrary code.
nvd
CVE-2021-38438P3HIGHCVSS 7.8≤ 3.302021-10-18
CVE-2021-38438 [HIGH] CWE-416 CVE-2021-38438: A use after free vulnerability in FATEK Automation WinProladder versions 3.30 and prior may be explo A use after free vulnerability in FATEK Automation WinProladder versions 3.30 and prior may be exploited when a valid user opens a malformed project file, which may allow arbitrary code execution.
nvd
CVE-2021-38442P3HIGHCVSS 7.8≤ 3.302021-10-18
CVE-2021-38442 [HIGH] CWE-119 CVE-2021-38442: FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a heap-corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process.
nvd
CVE-2020-16234P3HIGHCVSS 7.8≤ 3.282020-09-30
CVE-2020-16234 [HIGH] CWE-121 CVE-2020-16234: In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be explo In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code.
nvd
CVE-2021-38440P4LOWCVSS 3.3≤ 3.302021-10-18
CVE-2021-38440 [LOW] CWE-125 CVE-2021-38440: FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information.