cbcvebase.

Hp Openview Network Node Manager vulnerabilities

80 known vulnerabilities affecting hp/openview_network_node_manager.

Total CVEs
80
CISA KEV
1
actively exploited
Public exploits
25
Exploited in wild
1
Severity breakdown
CRITICAL52HIGH11MEDIUM16LOW1

Vulnerabilities

Page 1 of 4
CVE-2005-2773P1CRITICALCVSS 9.8KEVPoC≥ 6.2, ≤ 7.502005-09-02
CVE-2005-2773 [CRITICAL] CWE-77 CVE-2005-2773: HP OpenView Network Node Manager 6.2 through 7.50 allows remote attackers to execute arbitrary comma HP OpenView Network Node Manager 6.2 through 7.50 allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) node parameter to connectedNodes.ovpl, (2) cdpView.ovpl, (3) freeIPaddrs.ovpl, and (4) ecscmg.ovpl.
nvd
CVE-2010-2703P1CRITICALCVSS 10.0PoCv7.51v7.532010-07-28
CVE-2010-2703 [CRITICAL] CWE-119 CVE-2010-2703: Stack-based buffer overflow in the execvp_nc function in the ov.dll module in HP OpenView Network No Stack-based buffer overflow in the execvp_nc function in the ov.dll module in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53, when running on Windows, allows remote attackers to execute arbitrary code via a long HTTP request to webappmon.exe.
nvd
CVE-2009-4179P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2009-12-10
CVE-2009-4179 [CRITICAL] CWE-119 CVE-2009-4179: Stack-based buffer overflow in ovalarm.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, Stack-based buffer overflow in ovalarm.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allows remote attackers to execute arbitrary code via a long HTTP Accept-Language header in an OVABverbose action.
nvd
CVE-2011-3167P2CRITICALCVSS 10.0PoCv7.51v7.532011-11-02
CVE-2011-3167 [CRITICAL] CVE-2011-3167: Unspecified vulnerability in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote a Unspecified vulnerability in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to execute arbitrary code via unknown vectors, aka ZDI-CAN-1210.
nvd
CVE-2010-1553P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2010-05-13
CVE-2010-1553 [CRITICAL] CWE-119 CVE-2010-1553: Stack-based buffer overflow in getnnmdata.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.5 Stack-based buffer overflow in getnnmdata.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allows remote attackers to execute arbitrary code via an invalid MaxAge parameter.
nvd
CVE-2010-1554P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2010-05-13
CVE-2010-1554 [CRITICAL] CWE-119 CVE-2010-1554: Stack-based buffer overflow in getnnmdata.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.5 Stack-based buffer overflow in getnnmdata.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allows remote attackers to execute arbitrary code via an invalid iCount parameter.
nvd
CVE-2009-3849P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2009-12-10
CVE-2009-3849 [CRITICAL] CWE-119 CVE-2009-3849: Multiple stack-based buffer overflows in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7 Multiple stack-based buffer overflows in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allow remote attackers to execute arbitrary code via (1) a long Template parameter to nnmRptConfig.exe, related to the strcat function; or (2) a long Oid parameter to snmp.exe.
nvd
CVE-2010-1555P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2010-05-13
CVE-2010-1555 [CRITICAL] CWE-119 CVE-2010-1555: Stack-based buffer overflow in getnnmdata.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.5 Stack-based buffer overflow in getnnmdata.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allows remote attackers to execute arbitrary code via an invalid Hostname parameter.
nvd
CVE-2010-1961P2CRITICALCVSS 10.0PoCv7.51v7.532010-06-10
CVE-2010-1961 [CRITICAL] CWE-119 CVE-2010-1961: Buffer overflow in ovutil.dll in ovwebsnmpsrv.exe in HP OpenView Network Node Manager (OV NNM) 7.51 Buffer overflow in ovutil.dll in ovwebsnmpsrv.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to execute arbitrary code via unspecified variables to jovgraph.exe, which are not properly handled in a call to the sprintf function.
nvd
CVE-2010-1960P2CRITICALCVSS 10.0PoCv7.51v7.532010-06-10
CVE-2010-1960 [CRITICAL] CWE-119 CVE-2010-1960: Buffer overflow in the error handling functionality in ovwebsnmpsrv.exe in HP OpenView Network Node Buffer overflow in the error handling functionality in ovwebsnmpsrv.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to execute arbitrary code via a long, invalid option to jovgraph.exe.
nvd
CVE-2010-1552P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2010-05-13
CVE-2010-1552 [CRITICAL] CWE-119 CVE-2010-1552: Stack-based buffer overflow in the doLoad function in snmpviewer.exe in HP OpenView Network Node Man Stack-based buffer overflow in the doLoad function in snmpviewer.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allows remote attackers to execute arbitrary code via the act and app parameters.
nvd
CVE-2011-0267P2CRITICALCVSS 10.0PoCv7.51v7.532011-01-13
CVE-2011-0267 [CRITICAL] CVE-2011-0267: Multiple buffer overflows in nnmRptConfig.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and Multiple buffer overflows in nnmRptConfig.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allow remote attackers to execute arbitrary code via a long (1) schdParams or (2) nameParams parameter, a different vulnerability than CVE-2011-0266.
nvd
CVE-2011-0266P2CRITICALCVSS 10.0PoCv7.51v7.532011-01-13
CVE-2011-0266 [CRITICAL] CWE-119 CVE-2011-0266: Buffer overflow in nnmRptConfig.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allow Buffer overflow in nnmRptConfig.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to execute arbitrary code via a long nameParams parameter, a different vulnerability than CVE-2011-0267.2.
nvd
CVE-2009-4178P2CRITICALCVSS 10.0PoCv7.0.1v7.51+1 more2009-12-10
CVE-2009-4178 [CRITICAL] CWE-119 CVE-2009-4178: Heap-based buffer overflow in OvWebHelp.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, Heap-based buffer overflow in OvWebHelp.exe in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allows remote attackers to execute arbitrary code via a long Topic parameter.
nvd
CVE-2010-1964P2HIGHCVSS 7.5PoCv7.51v7.532010-06-17
CVE-2010-1964 [HIGH] CVE-2010-1964: Buffer overflow in ovwebsnmpsrv.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allow Buffer overflow in ovwebsnmpsrv.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to execute arbitrary code via unspecified parameters to jovgraph.exe, aka ZDI-CAN-683.
nvd
CVE-2007-6204P2CRITICALCVSS 10.0PoCv6.41v7.0.1+1 more2007-12-13
CVE-2007-6204 [CRITICAL] CWE-119 CVE-2007-6204: Multiple stack-based buffer overflows in HP OpenView Network Node Manager (OV NNM) 6.41, 7.01, and 7 Multiple stack-based buffer overflows in HP OpenView Network Node Manager (OV NNM) 6.41, 7.01, and 7.51 allow remote attackers to execute arbitrary code via unspecified long arguments to (1) ovlogin.exe, (2) OpenView5.exe, (3) snmpviewer.exe, and (4) webappmon.exe, as demonstrated via a long Action parameter to OpenView5.exe.
nvd
CVE-2008-1697P2CRITICALCVSS 10.0PoC≤ 7.53v7.0.1+1 more2008-04-08
CVE-2008-1697 [CRITICAL] CWE-119 CVE-2008-1697: Stack-based buffer overflow in ovwparser.dll in HP OpenView Network Node Manager (OV NNM) 7.53, 7.51 Stack-based buffer overflow in ovwparser.dll in HP OpenView Network Node Manager (OV NNM) 7.53, 7.51, and earlier allows remote attackers to execute arbitrary code via a long URI in an HTTP request processed by ovas.exe, as demonstrated by a certain topology/homeBaseView request. NOTE: some of these details are obtained from third party information.
nvd
CVE-2008-0067P2CRITICALCVSS 10.0PoCv7.512009-01-08
CVE-2008-0067 [CRITICAL] CWE-119 CVE-2008-0067: Multiple stack-based buffer overflows in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7 Multiple stack-based buffer overflows in HP OpenView Network Node Manager (OV NNM) 7.01, 7.51, and 7.53 allow remote attackers to execute arbitrary code via (1) long string parameters to the OpenView5.exe CGI program; (2) a long string parameter to the OpenView5.exe CGI program, related to ov.dll; or a long string parameter to the (3) getcvdata.exe,
nvd
CVE-2010-2709P2CRITICALCVSS 9.3PoCv7.51v7.532010-08-05
CVE-2010-2709 [CRITICAL] CWE-119 CVE-2010-2709: Stack-based buffer overflow in webappmon.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7 Stack-based buffer overflow in webappmon.exe in HP OpenView Network Node Manager (OV NNM) 7.51 and 7.53 allows remote attackers to execute arbitrary code via a long OvJavaLocale value in a cookie.
nvd
CVE-2008-3544P2CRITICALCVSS 9.0PoCv7.01v7.50+2 more2008-10-13
CVE-2008-3544 [CRITICAL] CWE-119 CVE-2008-3544: Multiple stack-based buffer overflows in ovalarmsrv in HP OpenView Network Node Manager (OV NNM) 7.5 Multiple stack-based buffer overflows in ovalarmsrv in HP OpenView Network Node Manager (OV NNM) 7.51, and possibly 7.01, 7.50, and 7.53, allow remote attackers to execute arbitrary code via a long (1) REQUEST_SEV_CHANGE (aka number 47), (2) REQUEST_SAVE_STATE (aka number 61), or (3) REQUEST_RESTORE_STATE (aka number 62) request to TCP port 2954.
nvd
Hp Openview Network Node Manager vulnerabilities | cvebase