Moxa Tn-5900 Firmware vulnerabilities

11 known vulnerabilities affecting moxa/tn-5900_firmware.

Total CVEs
11
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL6HIGH4MEDIUM1

Vulnerabilities

Page 1 of 1
CVE-2023-34215CRITICALCVSS 9.8≤ 3.32023-08-17
CVE-2023-34215 [HIGH] CWE-78 CVE-2023-34215: TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command-injection vulnerabilit TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the certification-generation function, which could potentially allow malicious users to execute remote code on affected devices.
nvd
CVE-2023-33239CRITICALCVSS 9.8≤ 3.32023-08-17
CVE-2023-33239 [HIGH] CWE-78 CVE-2023-33239: TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prio TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command injection vulnerability. This vulnerability stems from insufficient input validation in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.
nvd
CVE-2023-33238CRITICALCVSS 9.8≤ 3.32023-08-17
CVE-2023-33238 [HIGH] CWE-78 CVE-2023-33238: TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prio TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command injection vulnerability. This vulnerability stems from inadequate input validation in the certificate management function, which could potentially allow malicious users to execute remote code on affected devices.
nvd
CVE-2023-34213CRITICALCVSS 9.8≤ 3.32023-08-17
CVE-2023-34213 [HIGH] CWE-78 CVE-2023-34213: TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. T TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.
nvd
CVE-2023-34214CRITICALCVSS 9.8≤ 3.32023-08-17
CVE-2023-34214 [HIGH] CWE-78 CVE-2023-34214: TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prio TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command-injection vulnerability. This vulnerability stems from insufficient input validation in the certificate-generation function, which could potentially allow malicious users to execute remote code on affected devices.
nvd
CVE-2023-34216HIGHCVSS 8.1≤ 3.32023-08-17
CVE-2023-34216 [HIGH] CWE-22 CVE-2023-34216: TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prio TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command-injection vulnerability. This vulnerability derives from insufficient input validation in the key-delete function, which could potentially allow malicious users to delete arbitrary files.
nvd
CVE-2023-34217HIGHCVSS 8.1≤ 3.32023-08-17
CVE-2023-34217 [HIGH] CWE-22 CVE-2023-34217: TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prio TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command-injection vulnerability. This vulnerability stems from insufficient input validation in the certificate-delete function, which could potentially allow malicious users to delete arbitrary files.
nvd
CVE-2023-33237HIGHCVSS 8.8≤ 3.32023-08-17
CVE-2023-33237 [HIGH] CWE-863 CVE-2023-33237: TN-5900 Series firmware version v3.3 and prior is vulnerable to improper-authentication vulnerabilit TN-5900 Series firmware version v3.3 and prior is vulnerable to improper-authentication vulnerability. This vulnerability arises from inadequate authentication measures implemented in the web API handler, allowing low-privileged APIs to execute restricted actions that only high-privileged APIs are allowed This presents a potential risk of unauthorized
nvd
CVE-2023-3336MEDIUMCVSS 5.3≤ 3.32023-07-05
CVE-2023-3336 [MEDIUM] CWE-204 CVE-2023-3336: TN-5900 Series version 3.3 and prior versions is vulnearble to user enumeration vulnerability. The v TN-5900 Series version 3.3 and prior versions is vulnearble to user enumeration vulnerability. The vulnerability may allow a remote attacker to determine whether a user is valid during password recovery through the web login page and enable a brute force attack with valid users.
nvd
CVE-2021-46560CRITICALCVSS 9.8≤ 3.12022-01-26
CVE-2021-46560 [CRITICAL] CWE-77 CVE-2021-46560: The firmware on Moxa TN-5900 devices through 3.1 allows command injection that could lead to device The firmware on Moxa TN-5900 devices through 3.1 allows command injection that could lead to device damage.
nvd
CVE-2021-46559HIGHCVSS 7.5≤ 3.12022-01-26
CVE-2021-46559 [HIGH] CWE-345 CVE-2021-46559: The firmware on Moxa TN-5900 devices through 3.1 has a weak algorithm that allows an attacker to def The firmware on Moxa TN-5900 devices through 3.1 has a weak algorithm that allows an attacker to defeat an inspection mechanism for integrity protection.
nvd