Nexx Smart Alarm Nxal-100 vulnerabilities
5 known vulnerabilities affecting nexx/smart_alarm_nxal-100.
Total CVEs
5
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL1HIGH1MEDIUM3
Vulnerabilities
Page 1 of 1
CVE-2023-1748P2CRITICALCVSS 10.0≤ nxal100v-p1-9-12023-04-04
CVE-2023-1748 [CRITICAL] CWE-798 CVE-2023-1748: The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthen
The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for any customer.
nvd
CVE-2023-1750P3HIGHCVSS 7.1≤ nxal100v-p1-9-12023-04-04
CVE-2023-1750 [HIGH] CWE-639 CVE-2023-1750: The listed versions of Nexx Smart Home devices lack proper access control when executing actions. An
The listed versions of Nexx Smart Home devices lack proper access control when executing actions. An attacker with a valid NexxHome deviceId could retrieve device history, set device settings, and retrieve device information.
nvd
CVE-2023-1749P3MEDIUMCVSS 6.5≤ nxal100v-p1-9-12023-04-04
CVE-2023-1749 [MEDIUM] CWE-639 CVE-2023-1749: The listed versions of Nexx Smart Home devices lack proper access control when executing actions. An
The listed versions of Nexx Smart Home devices lack proper access control when executing actions. An attacker with a valid NexxHome deviceId could send API requests that the affected devices would execute.
nvd
CVE-2023-1751P4MEDIUMCVSS 5.3≤ nxal100v-p1-9-12023-04-04
CVE-2023-1751 [MEDIUM] CVE-2023-1751: The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.
nvd
CVE-2023-1752P4MEDIUMCVSS 4.3≤ nxal100v-p1-9-12023-04-04
CVE-2023-1752 [MEDIUM] CWE-287 CVE-2023-1752: The listed versions of Nexx Smart Home devices could allow any user to register an already registere
The listed versions of Nexx Smart Home devices could allow any user to register an already registered alarm or associated device with only the device’s MAC address.
nvd