cbcvebase.

Omron Nj101-1000 Firmware vulnerabilities

4 known vulnerabilities affecting omron/nj101-1000_firmware.

Total CVEs
4
CISA KEV
0
Public exploits
0
Exploited in wild
1
Severity breakdown
CRITICAL1HIGH3

Vulnerabilities

Page 1 of 1
CVE-2022-34151P2HIGHCVSS 8.1Exploited≤ 1.482022-07-04
CVE-2022-34151 [HIGH] CWE-798 CVE-2022-34151: Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all mo Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Ter
nvd
CVE-2022-31206P3CRITICALCVSS 9.8fixed in 1.492022-07-26
CVE-2022-31206 [CRITICAL] CWE-347 CVE-2022-31206: The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2 The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine cod
nvd
CVE-2022-33208P3HIGHCVSS 8.1≤ 1.482022-07-04
CVE-2022-33208 [HIGH] CWE-294 CVE-2022-33208: Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ ser Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Progra
nvd
CVE-2022-33971P3HIGHCVSS 7.5≤ 1.482022-07-04
CVE-2022-33971 [HIGH] CWE-294 CVE-2022-33971: Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 se Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication b
nvd