Phoenixcontact Automationworx Software Suite vulnerabilities

5 known vulnerabilities affecting phoenixcontact/automationworx_software_suite.

Total CVEs
5
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
HIGH5

Vulnerabilities

Page 1 of 1
CVE-2022-3737HIGHCVSS 7.8v1.892022-11-15
CVE-2022-3737 [HIGH] CWE-125 CVE-2022-3737: In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the in In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.
nvd
CVE-2022-3461HIGHCVSS 7.8v1.892022-11-15
CVE-2022-3461 [HIGH] CWE-119 CVE-2022-3461: In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ f In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.
nvd
CVE-2019-12871HIGHCVSS 8.8≤ 1.862019-06-24
CVE-2019-12871 [HIGH] CWE-416 CVE-2019-12871: An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and C An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation,
nvd
CVE-2019-12870HIGHCVSS 8.8≤ 1.862019-06-24
CVE-2019-12870 [HIGH] CWE-824 CVE-2019-12870: An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and C An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Uninitialized Pointer and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manip
nvd
CVE-2019-12869HIGHCVSS 8.8≤ 1.862019-06-24
CVE-2019-12869 [HIGH] CWE-125 CVE-2019-12869: An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and C An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-Of-Bounds Read, Information Disclosure, and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to mani
nvd