CVE-2020-7540CRITICALCVSS 9.8fixed in 2.102020-12-11
CVE-2020-7540 [CRITICAL] CWE-306 CVE-2020-7540: A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Mo A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP reques
nvd
CVE-2020-7539HIGHCVSS 7.5fixed in 2.102020-12-11
CVE-2020-7539 [HIGH] CWE-754 CVE-2020-7539: A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Serve A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the
nvd
CVE-2020-7541MEDIUMCVSS 5.3fixed in 2.102020-12-11
CVE-2020-7541 [MEDIUM] CWE-425 CVE-2020-7541: A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340 A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTT
nvd
CVE-2020-7533CRITICALCVSS 9.8fixed in 2.102020-12-01
CVE-2020-7533 [CRITICAL] CWE-287 CVE-2020-7533: CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
nvd
CVE-2017-6017HIGHCVSS 7.5v2.82017-06-30
CVE-2017-6017 [HIGH] CWE-400 CVE-2017-6017: A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC cau