Schneider-Electric Imp319-1Er Firmware vulnerabilities

15 known vulnerabilities affecting schneider-electric/imp319-1er_firmware.

Total CVEs
15
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL8HIGH6MEDIUM1

Vulnerabilities

Page 1 of 1
CVE-2018-7780CRITICALCVSS 9.8fixed in 3.29.692018-07-03
CVE-2018-7780 [CRITICAL] CWE-119 CVE-2018-7780: In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior t In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".
nvd
CVE-2018-7782HIGHCVSS 8.8fixed in 3.29.692018-07-03
CVE-2018-7782 [HIGH] CWE-522 CVE-2018-7782: In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior t In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
nvd
CVE-2018-7781HIGHCVSS 8.8fixed in 3.29.692018-07-03
CVE-2018-7781 [HIGH] CWE-311 CVE-2018-7781: In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior t In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
nvd
CVE-2018-7238CRITICALCVSS 9.8fixed in 3.29.672018-03-09
CVE-2018-7238 [CRITICAL] CWE-120 CVE-2018-7238: A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Profe A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.
nvd
CVE-2018-7229CRITICALCVSS 9.8fixed in 3.29.672018-03-09
CVE-2018-7229 [CRITICAL] CWE-798 CVE-2018-7229: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
nvd
CVE-2018-7231CRITICALCVSS 9.8fixed in 3.29.672018-03-09
CVE-2018-7231 [CRITICAL] CWE-20 CVE-2018-7231: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.
nvd
CVE-2018-7228CRITICALCVSS 9.8fixed in 3.29.672018-03-09
CVE-2018-7228 [CRITICAL] CWE-287 CVE-2018-7228: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.
nvd
CVE-2018-7232CRITICALCVSS 9.8fixed in 3.29.672018-03-09
CVE-2018-7232 [CRITICAL] CWE-20 CVE-2018-7232: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
nvd
CVE-2018-7233CRITICALCVSS 9.8fixed in 3.29.672018-03-09
CVE-2018-7233 [CRITICAL] CWE-20 CVE-2018-7233: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.
nvd
CVE-2018-7237CRITICALCVSS 9.1fixed in 3.29.672018-03-09
CVE-2018-7237 [CRITICAL] CWE-20 CVE-2018-7237: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'
nvd
CVE-2018-7236HIGHCVSS 8.1fixed in 3.29.672018-03-09
CVE-2018-7236 [HIGH] CWE-287 CVE-2018-7236: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
nvd
CVE-2018-7234HIGHCVSS 7.5fixed in 3.29.672018-03-09
CVE-2018-7234 [HIGH] CWE-295 CVE-2018-7234: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.
nvd
CVE-2018-7235HIGHCVSS 7.5fixed in 3.29.672018-03-09
CVE-2018-7235 [HIGH] CWE-20 CVE-2018-7235: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'
nvd
CVE-2018-7230HIGHCVSS 8.8fixed in 3.29.672018-03-09
CVE-2018-7230 [HIGH] CWE-611 CVE-2018-7230: A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67.
nvd
CVE-2018-7227MEDIUMCVSS 5.3fixed in 3.29.672018-03-09
CVE-2018-7227 [MEDIUM] CWE-287 CVE-2018-7227: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions pri A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.
nvd