Siemens Capital Embedded Ar Classic 431-422 vulnerabilities
11 known vulnerabilities affecting siemens/capital_embedded_ar_classic_431-422.
Total CVEs
11
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL4HIGH6MEDIUM1
Vulnerabilities
Page 1 of 1
CVE-2021-31346CRITICALCVSS 9.1fixed in *2021-11-09
CVE-2021-31346 [CRITICAL] CWE-1284 CVE-2021-31346: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unch
cvelistv5nvd
CVE-2021-31889CRITICALCVSS 9.1fixed in *2021-11-09
CVE-2021-31889 [CRITICAL] CWE-191 CVE-2021-31889: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FS
cvelistv5nvd
CVE-2021-31890CRITICALCVSS 9.1fixed in *2021-11-09
CVE-2021-31890 [CRITICAL] CWE-240 CVE-2021-31890: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchec
cvelistv5nvd
CVE-2021-31345CRITICALCVSS 9.1fixed in *2021-11-09
CVE-2021-31345 [CRITICAL] CWE-1284 CVE-2021-31345: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service co
cvelistv5nvd
CVE-2021-31881HIGHCVSS 7.5fixed in *2021-11-09
CVE-2021-31881 [HIGH] CWE-125 CVE-2021-31881: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
cvelistv5nvd
CVE-2021-31882HIGHCVSS 7.5fixed in *2021-11-09
CVE-2021-31882 [HIGH] CWE-119 CVE-2021-31882: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
cvelistv5nvd
CVE-2021-31883HIGHCVSS 7.5fixed in *2021-11-09
CVE-2021-31883 [HIGH] CWE-119 CVE-2021-31883: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
cvelistv5nvd
CVE-2021-31344MEDIUMCVSS 6.9fixed in *2021-11-09
CVE-2021-31344 [MEDIUM] CWE-843 CVE-2021-31344: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply
cvelistv5nvd
CVE-2021-25664HIGHCVSS 8.7fixed in *2021-04-22
CVE-2021-25664 [HIGH] CWE-835 CVE-2021-25664: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The functio
cvelistv5nvd
CVE-2021-25663HIGHCVSS 8.7fixed in *2021-04-22
CVE-2021-25663 [HIGH] CWE-835 CVE-2021-25663: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital E
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The functio
cvelistv5nvd
CVE-2019-13939HIGHCVSS 7.1fixed in *2020-01-16
CVE-2019-13939 [HIGH] CWE-20 CVE-2019-13939: A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC C
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions = V2.8.2 = V2.8.2 = V2.3 = V2.3x and = V2.3 = V2.3 = V2.3 = V2.3x and = V2.3 = V2.3 = V2.3 = V2.3 = V2.3 = V2.3x and = V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All
cvelistv5nvd