Siemens Scalance W700 Series Firmware vulnerabilities
2 known vulnerabilities affecting siemens/scalance_w700_series_firmware.
Total CVEs
2
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL1MEDIUM1
Vulnerabilities
Page 1 of 1
CVE-2013-4652P2CRITICALCVSS 10.0≤ 4.4.02013-08-01
CVE-2013-4652 [CRITICAL] CVE-2013-4652: Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
nvd
CVE-2013-4651P4MEDIUMCVSS 6.6≤ 4.4.02013-08-01
CVE-2013-4651 [MEDIUM] CWE-255 CVE-2013-4651: Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate ac
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
nvd