Siemens Simatic Cp 443-1 Opc Ua vulnerabilities
5 known vulnerabilities affecting siemens/simatic_cp_443-1_opc_ua.
Total CVEs
5
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
HIGH5
Vulnerabilities
Page 1 of 1
CVE-2019-13946HIGHCVSS 7.5vAll versions2020-02-11
CVE-2019-13946 [HIGH] CWE-400 CVE-2019-13946: Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation wh
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation when multiple legitimate diagnostic package
requests are sent to the DCE-RPC interface.
This could lead to a denial of service condition due to lack of memory
for devices that include a vulnerable version of the stack.
The security vulnerability could be
cvelistv5nvd
CVE-2019-6575HIGHCVSS 7.5vAll versions2019-04-17
CVE-2019-6575 [HIGH] CWE-248 CVE-2019-6575: A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions = V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanc
cvelistv5nvd
CVE-2019-6568HIGHCVSS 7.5vAll versions2019-04-17
CVE-2019-6568 [HIGH] CWE-125 CVE-2019-6568: The webserver of the affected devices contains a vulnerability that may lead to
a denial of service
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploita
cvelistv5nvd
CVE-2017-2681HIGHCVSS 7.1vAll versions2017-05-11
CVE-2017-2681 [HIGH] CWE-400 CVE-2017-2681: Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected pro
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
cvelistv5nvd
CVE-2017-2680HIGHCVSS 7.1vAll versions2017-05-11
CVE-2017-2680 [HIGH] CWE-400 CVE-2017-2680: Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affect
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
cvelistv5nvd